  • Page 1 NINFA 32 MC ISTRUZIONI PER L’USO L'INSTALLAZIONE E LA MANUTENZIONE INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIEN INSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTO INSTRUÇÕES DE INSTALAÇÃO, UTILIZAÇÃO E MANUTENÇÃO...
  • Page 2: Declaration Of Conformity

    NINFA 32 MC • Carefully read the warnings in this instruction book- • In case the unit breaks down and/or functions poorly, let since they provide important information on safe deactivate it, do not make any attempt to repair it or installation, use and maintenance.
  • Page 3: Table Of Contents

    NINFA 32 MC 1 Operating instructions ......................30 1.1 Introduction............................30 1.2 Control panel ............................30 1.3 Turning on and off ..........................32 1.4 Adjustments............................33 2 Installation ..........................38 2.1 General Instructions ..........................38 2.2 Installation place........................... 38 2.3 Plumbing connections .......................... 38 2.4 Gas connection ............................
  • Page 4: Operating Instructions

    Please read this manual carefully since it provides important information on safe installation, use and maintenance. NINFA 32 MC is a high-efficiency heat generator for heating and domestic hot water production, running on natural gas or LPG, equipped with an atmospheric burner with electronic ignition and microprocessor control system, and designed for installation indoors or outdoors in a partially protected place (in compliance with EN 297/A6) for temperatures as low as -5°C (-15°C with optional antifreeze kit).
  • Page 5 NINFA 32 MC Indication during operation Heating A heating demand (generated by the Room Thermostat or Remote Timer Control) is indicated by lighting up of the ra- diator (detail 5 - fig. 1). The multifunction display (detail 9 - fig. 1) shows the heating sensor temperature.
  • Page 6: Turning On And Off

    NINFA 32 MC 1.3 Turning on and off Boiler not electrically powered fig. 5 - Boiler not electrically powered The antifreeze system does not work when the power and/or gas to the unit are turned off. To avoid damage caused by freezing during long idle periods in winter, it is advisable to drain all water from the boiler, DHW circuit and system;...
  • Page 7: Adjustments

    NINFA 32 MC When the boiler is turned off, the electronic board is still powered. Domestic hot water and heating operation are disabled. The antifreeze system stays on. To re-light the boiler, turn the selector (detail 3 fig. 1) to (winter) or (summer).
  • Page 8 NINFA 32 MC Domestic hot water (DHW) temperature adjustment Operate the DHW knob (detail 2 - fig. 1) to set the temperature between 40°C (min.) and 55°C (max.); fig. 11 Room temperature adjustment (with optional room thermostat) Using the room thermostat, set the temperature desired in the rooms. If the room thermostat is not installed the boiler will keep the heating system at its setpoint temperature.
  • Page 9 NINFA 32 MC Compensation curve and curve shift Turn the selector (detail 3 - fig. 1) to RESET for 5 seconds and then to (winter) or (summer) and “CU” will be displayed. Operate the DHW knob (detail 2 - fig. 1) to adjust the required curve from 1 to 10 according to the characteristic (fig. 14).
  • Page 10 NINFA 32 MC If the room temperature is lower than the required value, it is advisable to set a higher order curve and vice versa. Pro- ceed by increasing or decreasing in steps of one and check the result in the room.
  • Page 11 NINFA 32 MC Water system pressure adjustment The filling pressure with system cold, read on the boiler water gauge, must be approx. 1.0 bar. If the system pressure falls to values below minimum, the boiler card will activate fault F37 (fig. 16).
  • Page 12: Installation

    NINFA 32 MC 2. Installation 2.1 General Instructions BOILER INSTALLATION MUST ONLY BE PERFORMED BY QUALIFIED PERSONNEL, IN ACCORDANCE WITH ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL MANUAL, THE PROVISIONS OF CURRENT LAW, THE PRE- SCRIPTIONS OF NATIONAL AND LOCAL STANDARDS AND THE RULES OF PROPER WORKMANSHIP.
  • Page 13: Gas Connection

    NINFA 32 MC System water charcteristics In the presence of water harder than 25° Fr (1°F = 10ppm CaCO ), the use of suitably treated water is advisable in order to avoid possible scaling in the boiler. The treatment must not in any case reduce the hardness to values below 15°F (Decree 236/88 for uses of water intended for human consumption).
  • Page 14: Electrical Connections

    NINFA 32 MC 2.5 Electrical connections Connection to the electrical grid The unit's electrical safety is only guaranteed when correctly connected to an efficient earthing system exe- cuted according to current safety standards. Have the efficiency and suitability of the earthing system checked by professionally qualified personnel.
  • Page 15: Service And Maintenance

    NINFA 32 MC 3. Service and maintenance All adjustment, conversion, start-up and maintenance operations described below must only be carried out by Qualified Per- sonnel (meeting the professional technical requirements prescribed by current regulations) such as those of the Local After- Sales Technical Service.
  • Page 16 NINFA 32 MC Burner pressure adjustment Since this unit has flame modulation, there are two fixed pressure settings: minimum and maximum, which must be those given in the technical data table according to the type of gas. • Connect a suitable pressure gauge to the pressure point “B” located downstream of the gas valve.
  • Page 17 NINFA 32 MC Service Menu The card Service Menu is accessed by turning the selector (detail 3 - fig. 1) to RESET for 10 seconds and then to (winter) or (summer). Use the heating knob (detail 1 - fig. 1) to select “tS”, “In”, “Hi” or “rE”. “tS” means Transparent Parameters Menu, “In”...
  • Page 18 NINFA 32 MC “In” - Information Menu The card can display the following information: Table. 3 Heating NTC sensor (°C) between 05 and 125 °C DHW NTC sensor (°C) between 05 and 125 °C Not used External NTC sensor (°C) between -30 and 70 °C (Negative values...
  • Page 19: Start-Up

    NINFA 32 MC 3.2 Start-up Checks to be made at first lighting, and after all maintenance operations involving disconnection from the sys- tems or an intervention on safety devices or parts of the boiler: Before lighting the boiler • Open any on-off valves between the boiler and the systems.
  • Page 20 NINFA 32 MC Opening the casing To open the boiler casing: Undo the four screws A Lower the door Lift and remove the casing B Before carrying out any operation inside the boiler, disconnect the electrical power supply and close the gas cock upstream.
  • Page 21: Troubleshooting

    NINFA 32 MC 3.4 Troubleshooting Diagnostics The boiler is equipped with an advanced self-diagnosis system. In case of a boiler anomaly, the display will flash to- gether with the fault symbol (detail 22 - fig. 1) indicating the fault code.
  • Page 22: Technical Data And Characteristics

    NINFA 32 MC 4. Technical data and characteristics 4.1 Dimensions and connections Ø141 76,5 61,5 61 80,5 80,5 fig. 24 - Dimensions and connections Heating system delivery DHW outlet Gas inlet DHW inlet Heating system return Safety valve drain cod. 3540G380 - 02/2007 (Rev. 00)
  • Page 23: General View And Main Components

    NINFA 32 MC 4.2 General view and main components fig. 25 - General view Gas inlet DHW temperature sensor DHW outlet Gas valve DHW inlet Expansion tank System delivery Anti-backflow device System return Ignition and detection electrode Safety valve Diverter valve...
  • Page 24: Plumbing Circuit

    NINFA 32 MC 4.3 Plumbing circuit fig. 26 - Plumbing circuit Gas inlet Gas valve DHW outlet Expansion tank DHW inlet Heating system cock System delivery Anti-backflow device System return Ignition and detection electrode Safety valve Diverter valve Burner assembly...
  • Page 25: Technical Data Table

    NINFA 32 MC 4.4 Technical data table The column on the right gives the abbreviation used on the technical data plate. Data Unit Setting Max heating power 34.4 Min heating power 11.5 Max heating system heating power 31.3 Min heating system heating power Max hot water heating power 31.3...
  • Page 26: Diagrams

    NINFA 32 MC 4.5 Diagrams Pressure - power diagrams NATURAL GAS Losses of load / head of circulators H [m H Q [l/h] 1.000 1.500 2.000 Boiler losses of head 1 - 2 - 3 Circulator speed cod. 3540G380 - 02/2007 (Rev. 00)
  • Page 27: Wiring Diagram

    NINFA 32 MC 4.6 Wiring diagram fig. 27 - Wiring diagram DHW circulating pump 114 Water pressure switch DHW temperature sensor 126 Fume thermostat Gas valve 136 Flow meter Modureg 138 External sensor Room thermostat (Optional) 139 Remote Timer Control - Opentherm (Optional)
  • Page 28 BRUCIATORI CALDAIE MURALI E TERRA A GAS GRUPPI TERMICI IN GHISA E IN ACCIAIO GENERATORI DI ARIA CALDA TRATTAMENTO ACQUA CONDIZIONAMENTO Le illustrazioni e i dati riportati sono indicativi e non impegnano. La LAMBORGHINI si riserva il diritto di apportare senza obbligo di preavviso tutte le modifiche che ritiene più...