4.
INSTALLATION
Si\\n\'
by Dometic GROUP
Ni\\U\'
by Dometic GROUP
4. INSTALLATION
U
BURNER
INJECTOR ORIFICE (mm)
STAMPED N!l
AUXILIARY (0 47mm)
0.57
57
SEMI-RAPID (0 62mm)
0.72
72
OVEN
0.57
57
GRILL
0.67
67
The connection of the gas pipe to the appliance (1/4 BSPT female) must be made with a rigid metal pipe.The
pipe work and fittings shall be free from defects and of an approved type.
Once installed. the installation must be checked for leaks by means of an approved testing method.
Do not use a solution of soap and water.
WARNING
Never use a naked flame to check for gas leaks.
The supply cord must be positioned in such a way that it never reaches a temperature
of 75°C above ambient in any point.
The plug must be easy to access after installation.
Always disconnect electrical power before working on or servicing the) appliance.
For connecting to the mains power supply use a socket.
If the supply cord (H05RR-F 3x0,75mm
2
)
is damaged. it must be replaced by the manufacturer or its service
agent or a similarly qualified person in order to avoid a hazard.
4.5
Fixture
CAUTION
This appliance is to be fixed and secured to the cabinet as described in FIG. 6 - PG.
25.
CAUTION
WARNING
4.6
Testing (before leaving)
4.4
Electric connection
Low voltage I2 V
"-='"
This chapter concerns only models marked 12 V
"-='"
on the appliance data plate.
CAUTION
Ignite all burners both individually and concurrently to ensure correct operation of gas valves. burners and
ignition. Turn gas taps to low flame position and observe stability of the flame for each burner individually and
concurrently. Ensure correct operation of the flame failure protection.
Depending on the type of gas used. the appearance of the flame is as follows:
Propane: flame with blue centre and well-defined contour.
Butane: flame with light yellow tips when igniting the burner. gradually intensifying as the burner heats.
In case the appliance fails to operate correctly after all checks have been carried
out, shut off the gas supply at the main gas tap and refer to the authorized service
CAUTION
provider in your area.
When satisfied with the appliance. please instruct the user on the correct method of operation.
WARNING
Absolutely do not connect the appliance to the mains voltage (230 V-), this would
destroy the components and cause a hazard for the user.
CAUTION
This appliance must be connected to a 12V
"-='"
source.The circuit must be protected
by a fuse of no more than 3 Ampere.
Ensure that the polarity of the connection is correct!
CAUTION
WARNING
To connect the appliance use a 1.5 mm
2
double red and black wire and wire to the terminal junction box
located at the rear of the appliance with the wording "+ 12 V"-="'- ".The red terminal is the positive pole and
the black terminal is the negative pole.
High voltage 230-240 V-
This chapter refers only to the models listed in the table below.
Model
CU40 IPE - CU402PE - CU403PE
Nominal voltage
230-240V-
Nominal power
800W
4.6.1
Test point
For models PI... MO... CU...
The test point is supplied loose with the appliance (see picture in FIG. 7 PG. 29). Remove one burner head. the
injector and screw in test point fitting. The pressure is measured with the relevant burner gas valve on high
flame and with an inlet pressure of 2.75 kPa.
For models FO...
The test point is fitted on the main gas pipe. Remove the front plastic plaque (see picture in FIG.8 PG. 29) and
remove the screw. The pressure is measured with an inlet pressure of 2.75 kPa.
In these models there is an electric plate in the hotplate.
WARNING
WARNING
. When connecting direct to the mains supply, it is necessary to install a circuit
breaker which allows for disconnecting and isolating the appliance from the mains
in the event of overvoltage III conforming to installation regulations.
For modelsVN555
The test point is fitted on the main gas pipe. Remove the screw. The pressure is measured with an inlet
pressure of 2.75 kPa.
14