Self-Test - Furuno FR-2155 Service Manual

Hide thumbs Also See for FR-2155:
Table of Contents

Advertisement

4.4 Self-test

Test Menu
Press [RADAR MENU], [0], [0], [0], [3], and [ENTER] in this order, and the self-test result
display will appear after several seconds. Figure 4.2 shows the self-test result display. If any
error has been found in circuitry, NG appears instead of OK. The self-test is carried out at every
power-up, not when the keys are pressed. If the self-test detects an error, the message SYSTEM
FAIL appears at the lower right of the screen.
Radar system
program number
(MAIN board)
ARP program
number
(ARP board)
RP program
number
(RP board)
Test for PM and Degauss switches
Key and knob test
(BRILLIANCE, A/C RAIN, A/C SEA, and GAIN knobs are not tested.)
FR-2105
PROGRAM NO
MAIN
0359149101
ARP
1859038104
DSP
1859039101
RP
0359150101
DRAM
RP BOARD BAT
RP CARD 1
CARD 1 BAT
ANTENNA SPEED 0.0RPM
TRIG FREQ
MAG CURRENT
R. MONITOR
TUNE IND
123
EBL test
CH1 $GPGLL,3445.000, N, 13521.000,E <CR> <LF>
IEC61162 signal input to J450 is monitored.
Figure 4.2 Self-test Result Display
ROM Test
RAM Test
TEST
ROM
RAM
CRAM
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
CARD 2
OK
CARD2 BAT
0Hz
4.9V
1.8V
2.5V
002
VRM test
4-7
CRAM Test
DIPSW
1234
0000
DIP switch setting,
S1 on ARP board
0000
(#1 to #4 from left)
0 : on, 1 : off
OK
DIP switch setting,
OK
S1 on RP board
0 : on, 1 : off
251
008
Trackball test
FR2115-SME-45

Hide quick links:

Advertisement

Table of Contents
loading