Power Supply Unit (Psu-001) - Furuno FR-2155 Service Manual

Hide thumbs Also See for FR-2155:
Table of Contents

Advertisement

2.34 Power Supply Unit (PSU-001)

When the power switch on the display unit is turned on, 100/110/115 Vac is supplied from the
PSU-004 to PSU-001. Tap-selection on the transformer T804 is required depending on ship's
mains. For the ship's mains of 220/230 Vac, the transformer RU-1758 is required between the
PSU-004 and the PSU-001. The PSU-001 generates TXHV of 790 Vdc, magnetron heater volta-
ge of 8.2 to 8.9 Vdc, +12V, and –12V. R813 adjusts the magnetron heater voltage if the rated
value is not obtained by R811 and R812 in the scanner unit especially when the cable is long.
TXHV is not generated when MAG ERROR signal is received from the transceiver unit. A de-
fective magnetron and open-circuit of the pulse-transformer T801 generates the MAG ERROR
signal. Over-current protectors are provided for magnetron heater, +12 V, and –12 V lines.
100/110/115 VAC
SCANNER MOTOR
220VAC 3
50Hz
220VAC 3
60Hz
24VDC
100VAC
(De-icer option)
FL801
1
5
6
100V110V 115V
T804
24V
03P6667 A
100VAC
HM801
TX-HV
03P6680
Hour meter
03P6810
TX-HV Error
MAG Error
CR1
12V, Heater Error
CR2
12V
03P9003
Heater
R813 (4/10W)
(MAG Heater Voltage Adj.)
S801
2-39
100VAC
Fan Motor
TX-HV
(+790 VDC)
TX-Sig
MAG ERROR
M801
TX-HV Moniter
12V
CR801
MAG HEATER
Output
Output