BioAxs 9800IR™ Installation & Operations Manual. Version 1.9

Wiring Installation

Door Commander Module (DCM) Connections

DCM Ethernet Connection (LAN)
The BioAxs 9800IR™ Door Commander Module (DCM) requires a network connection to the
NextgenID Command Center™ server across a 10/100 Mb/s Ethernet network. A standard RJ45
Cat 5 Network Jack is provided on the rear panel of the DCM
Always consult with your NextgenID support representative and/or the local site Network
Note
Administrator before connecting the BioAxs 9800IR™ system to any existing networks within a
facility to ensure the proper network hardware and software security policies have been
implemented.
DCM Communications Extender
Using the supplied USB host cable, connect the DCM Communications Extender
USB 1 connection on the front panel of the DCM
Access Panel Video
Access Panel video is carried over coaxial cable from the J12 connector on the BioAxs 9800IR™
Access Panel to the composite video in input located on the rear panel of DCM. Terminate the
coaxial cable with a male RCA video connector. Plug the terminated cable into the composite
video in (access panel video) input on the rear panel of the DCM
Iris Recognition Video Frame Grabber Connection (FGB3000)
Iris recognition Video is carried over coaxial cable from the BNC Video connector on the BioAxs
9800IR™ Access Panel to the FGB3000 BNC video CH1 input located on the rear panel of DCM.
Terminate the coaxial video cable with a female BNC video connector. Plug the terminated cable
into the Channel 1 (CH1) input on the rear panel of the DCM