Chapter 6: Installation

Door Commander Module Installation

The Door Commander Module (DCM) is an industrial small form factor computer that is included
with each BioAxs 9800IR™ system. The DCM and BioAxs 9800IR™ must be located within 100
°
°
° -
meters of one another. Operating temperature range for the DCM is 32
F to 140
F (0
60C).
Located with the DCM is the DCM Communications Extender, this device is responsible for
relaying communications between the BioAxs 9800IR™ Access Panel and the DCM. The
Communications Extender plugs directly into an available USB port on the DCM.
The DCM and the DCM Communications Extender should be powered thru an Uninterruptible
Power Supply (UPS) (Battery Backup device rated at least 750 VA.
The following sections layout the typical installation procedures for the DCM unit and associated
devices.

Mount the Door Commander Module (DCM) Unit

Upon choosing the location for the DCM
(see Chapter 1: Locating the Door Commander
Module),
Mount the DCM in the appropriate configuration (Rack or Wall mount) using the supplied
mounting brackets.
USB 2
Power On
Power
Indicator LED
USB 1
Switch
Figure 7 DCM Front View
Copyright ©2004 NextgenID, Ltd. All Rights Reserved
25