BioAxs 9800IR™ Installation & Operations Manual. Version 1.9
Isolated from other equipment
Regulated and filtered
Protected by means of emergency power and/or battery backup providing at least 2
hours emergency backup power
Never connect the power supply to any device or component that may put transients on
the power supply line or cause the power signal to fluctuate improperly.
See
Chapter 3: Hardware Specifications
1. Amperage requirements may vary based on optional accessory and external device load.

Earth Ground

In order to protect the BioAxs 9800IR™ Access Panel device from electro-static discharge (ESD)
The access panel requires a home run connection to Earth Ground
Warning: NextgenID may consider your warranty void if there is an improper earth ground
connection to the BioAxs 9800IR™ Access Panel
1. See
Chapter 3: Hardware Specifications
2. See
Chapter 4: Wiring Specifications

Cabling Runs / Conduit Installation

Consult local building codes and regulations when making cabling runs. The installer should
make every effort to minimize the amount of exposed conduit.

Installation Tools Required

RJ45 Crimper
Wire Cutters / Strippers
Coax RCA Crimper
Mini Screw Driver Set
Drill and Drill Bits for mounting hardware and accessories to walls
Carpenters Level
Tape Measure
Fish Tape – Pull Wire

Customer / Installer Supplied Hardware and Cabling

Below is a typical list of additional items required to install your BioAxs 9800IR™ Access Control
System. Due to the variances in local building codes and regulations, these items are to be
supplied by the customer/ installer. Please refer to the appropriate chapters in this document for
specific hardware and wiring specifications as well as recommended vendors and item part
numbers.
Magnetic Door Sensor Switch
Magnetic Door Latch Or Door Strike (Up to 1Amp @ 12V-24V DC Load)
UL-Listed Class II 24V Linear Power Supply rated at 3-4 amps
should be sufficient for at least 2 Hours of continuous usage.
Copyright ©2004 NextgenID, Ltd. All Rights Reserved
for additional information
for specific hardware specifications
for details on specific cabling types
1
1, 2
.
1,3
1.
Battery backup capacity