Serial Interface - Argox X-1000VL User Manual

Xellent series industrial barcode printer
Hide thumbs Also See for X-1000VL:
Table of Contents

Advertisement

Serial Interface

The RS-232 connector on the printer side is a female, DB-9.
Pin
1
No function
Received Data,
2
RxD
Transmitted Data,
3
TxD
4
No function
5
GND
6
No function
Request to Send,
7
RTS
8
Clear to Send, CTS
9
+5V
Note: Pin 9 is reserved for a KDU (keyboard device unit). Do not
connect this pin if you use a general host such as a PC.
Signal
119
Description
Shorted to Pin - 6
Input. Serial "Received Data"
Output. Serial "Transmitted
Data".
No connection
Signal Ground
Shorted to Pin - 1
Output. Used as the control
signal for "H/W Flow Control "
Input. Used as the control signal
for "H/W Flow Control"
Output. Pin 9 is reserved for
KDU (keyboard device unit)

Hide quick links: