INSTALLATION
Continued
PRESSURE TESTING HEATER GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure 18,
page 15).
2. Open main gas valve located on or near gas
meter for natural gas or open propane/LP
supply tank valve.
3. Make sure control knob of heater is in the OFF
position.
4. Check all joints from equipment shutoff
valve to control valve (Manually-Controlled
Models), or to gas control (Remote-Ready
Models) (see Figures 19 and 20, page 15).
Apply noncorrosive leak detection fluid to all
joints. Bubbles forming show a leak.
5. Correct all leaks at once.
6. Light heater (see Operating Heater, page 17).
Check all other internal joints for leaks.
7. Turn off heater (see To Turn Off Gas to Appli-
ance, page 18 for Manually-Controlled Mod-
els, or page 20 for Remote-Ready Models).

INSTALLING LOGS

WARNING: Failure to position
the parts in accordance with these
diagrams or failure to use only
parts specifically approved with
this heater may result in property
damage or personal injury.
CAUTION: After installa-
tion and periodically thereafter,
check to ensure that no flame
comes in contact with any log.
With the heater set to High, check
to see if flames contact any log. If
so, reposition logs according to
the log installation instructions
in this manual. Flames contact-
ing logs will create soot.
It is very important to install the logs exactly as
instructed. Do not modify logs. Only use logs
supplied with heater.
1. Place one-piece log set on grate to fit as illustrated
in Figure 21 for Vintage Oak models and Figure 22
for Golden Oak models. For Vintage Oak models
make sure bottom of front log is in front of "U"-
shaped cutout in center of chassis (see Figure 21).
For Golden Oak models make sure middle section
at bottom of log set is seated into "U"-shaped
cutout in center of chassis (see Figure 22).
Available from Allparts Equipment and Accessories - 1-877-475-5660 - www.allpartsinc.com
Note: 36" models have more features but fit on the
chassis the same. Log will fit securely on chassis.
IMPORTANT: Make sure log does not cover
any burner ports (see Figures 23 or 24).
2. Place lava rock around base of heater if desired.
One-Piece
Log Set
Chassis
Figure 21 - Installing Vintage Oak One-
Piece Log Set
One-Piece
Log Set
Chassis
Figure 22 - Installing Golden Oak One-
Piece Log Set
Burner
Ports
Figure 23 - Installing Vintage Oak One-
Piece Log Set (Top View)
Burner
Ports
Figure 24 - Installing Golden Oak One-
Piece Log Set (Top View)
Burner
"U"-shaped
Cutout in
Chassis
Middle
Section at
Bottom of
Log Set
Burner
"U"-shaped
Cutout in Chassis
One
Piece
Log
Set
One
Piece
Log
Set