JOHNSON SYSTEMS JS-ICON 2410 User Manual page 17

Dimmer rack
Table of Contents

Advertisement

3.
SNAPSHOT
Record DMX levels into the backup scenes.
Provides a quick and easy way to save control channel levels into each of the
01 to 24 backup scenes using a DMX source.
Press EXECUTE to enter the menu and activate snapshot mode.
SAVE >01
Press MENU (
SCENE>24
Press EXECUTE to store DMX levels in the selected scene.
SURE ???
Press EXECUTE if you are sure the DMX levels are set as intended.
DONE !!!
DMX levels have now been stored in the selected scene.
NO RX!
DMX is not being received on either input, so a snapshot is not possible.
Press ESCAPE to back-up within the menu, or exit/deactivate snapshot mode.
Press RESET to exit/deactivate snapshot mode.
4.
DIM TEST
Test the dimmer outputs one at a time, or all at once.
A technician's best friend! Used for troubleshooting the dimmer outputs and field
wiring to the load.
Press EXECUTE to enter the menu and activate dimmer test mode.
D 01L>00
Displays the active dimmer (D) and the test level (L).
D 01L>50
Press MENU (
D 01L>FL
Press ESCAPE to toggle the test level from full-on (FL) and off (00).
D>01L FL
Press EXECUTE to toggle between the dimmer (D>) and the test level (L>).
D>ALL FL
Press MENU (
Press ESCAPE or RESET to exit the menu.
The menu will automatically timeout after 2 minutes of inactivity.
5.
MONITOR
View the control level to each dimmer output.
The dimmer control level is displayed as a 9-bit value from 000 to 512. This menu
does not timeout automatically and will continue to monitor indefinitely.
Press EXECUTE to enter the menu and activate monitor mode.
D>01L000
Press MENU (
D>24L512
Display shows dimmer 24 has full-on control.
Press ESCAPE or RESET to exit the menu.
NOTE: The control value will not reach 512 when voltage output limiting is activated,
or when regulation is enabled and the line voltage is greater than 118 VAC.
6.
ADDRESS
Set the DMX start address.
The DMX start address can be assigned from 001 to 512, and is common to both
DMX inputs. When DMX MODE is set for DMX A+B operation, each of the DMX
inputs can be assigned to a separate DMX start address. The DMX inputs are merged
and DMX-B is offset by the number of DMX-A channels.
Press EXECUTE to enter the menu.
DMXA>001
Displays the current DMX start address for both DMX inputs.
DMXA>512
Press MENU (
DMXA>001
Press both MENU (
DMXA>025
Press EXECUTE to save the selected DMX start address.
DMXB>001
* Press EXECUTE to advance to select the DMX-B start address.
DMXB>512
* Press MENU (
#CHA=>01
* Press EXECUTE to advance to select the number of DMX-A channels.
#CHA=>24
* Press MENU (
Press ESCAPE to exit the menu and save the selected DMX start address.
Press RESET to exit the menu without saving.
The menu will automatically timeout after 2 minutes of inactivity and save.
NOTE: * DMX MODE must be set for DMX A+B operation to access this feature.
NOTE: DMX O/P must be set to OFFSET mode for this menu to function.
www.johnsonsystems.com
) to select a different scene from 01 to 24.
) to select the desired test level.
) to select the active dimmer from 01 to 24 or ALL.
) to select the dimmer (D) output to monitor from 01 to 96.
) to modify and select the desired DMX start address.
) simultaneously to toggle to DMX start address 001.
) to modify and select the desired DMX start address.
) to modify the number of DMX-A channels from 01 to 24.
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Js-icon 620Js-icon 2413Js-icon 1220Js-icon 1210

Table of Contents