Quick Programming Reference To System Configuration Menu Items - JOHNSON SYSTEMS JS-ICON 2410 User Manual

Dimmer rack
Table of Contents

Advertisement

Quick Programming Reference
1. SCENESET
Enable and setup 24 different backup scenes.
2. FADETIME
Set the fade time for each of the 24 scenes from 0 to 99 seconds.
3. SNAPSHOT
Record DMX levels into the backup scenes.
4. DIM TEST
Test the dimmer outputs one at a time, or all at once.
5. MONITOR
View the control level to each dimmer output.
6. ADDRESS
Set the DMX start address.
7. DMX MODE
Configure the mode of the on-board DMX protocol manager.
8. 2 RM SET
Set the two room assignment for each of the dimmer outputs.
9. DMXA TRM
Enable or disable termination on the DMX A input.
10. DMXB TRM
Enable or disable termination on the DMX B input.
11. DMX O/P
Configure the on-board DMX protocol manager for offset or patch mode.
12. DMXA PAT
Patch the 24 dimmer (PWM) outputs to any DMX A input channel.
13. DMXB PAT
Patch the 24 dimmer (PWM) outputs to any DMX B input channel.
14. SH TIME
Set the DMX status hold time from 0 to 99 minutes or infinite.
15. DC PATCH
Configure the dimmer to channel patch for the dimmer rack.
16. DIM CURV
Configure the dimmer curve for each output.
17. VOUT LIM
Set the maximum RMS output voltage for each dimmer.
18. REGULATE
Enable or disable the dimmer output voltage regulation.
19. ANA MODE
Configure the analog inputs for normal or load shed mode.
20. ANA PTCH
Patch the analog inputs to any combination of control channels.
21. ANA TEST
View the control level for each of the analog inputs.
22. ANA FLTR
Apply a noise filter on the analog inputs of up to 1 Volt.
23. ANA BLOC
Enable or disable the analog inputs when DMX is being received.
24. STANDBY
Enable or disable the power savings standby mode.
25. TEST INC
Set the test increment units to percent or hexadecimal.
26. OC MODE
Configure the input trigger parameters for the open collector output.
27. AUX IN
Select which scene the auxiliary input will trigger/enable.
28. L-BUTTON
Set the mode of the local buttons to scene, bump or disabled.
29. S-ALARM
Select the level and control channels triggered by the security alarm input.
30. F-ALARM
Select the level and control channels triggered by the fire alarm input.
31. Ø-PATCH
Set the zero-cross phase reference for each dimmer control output circuit.
32. WARMING
Turn the "lamp warming" feature on or off.
33. POLARITY
Set the PWM output control polarity. Locked for factory use only!
34. LINE V
View the RMS line voltage for each power phase.
35. LINE F
View the line frequency of phase A.
36. REM TEMP
View the temperature of the remote temperature sensor.
37. CTL TEMP
View the temperature of the microcontroller.
38. RTIME
View the total run time of the microcontroller.
39. HARD-KEY
View the microcontroller's unique six-character hard-key code.
40. SERIAL#
View the microcontroller's unique six-character silicone serial number.
41. VERSION
View the microcontroller's firmware version.
42. EEPROM
View the type of EEPROM memory module plugged in.
43. FW-LOAD
Load new firmware into the MADD-24 via the EEPROM memory module.
44. RESTORE
Restore parameters saved in the EEPROM memory module.
45. BACKUP
Backup parameters and save them in the EEPROM memory module.
46. PRINTOUT
Print various system configuration settings using a hand held infrared printer.
47. DEFAULTS
Set various system configuration settings to the factory default.
48. LCD VIEW
Adjust the contrast of the LCD Display for optimum viewing.
www.johnsonsystems.com
to System Configuration Menu Items
15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Js-icon 620Js-icon 2413Js-icon 1220Js-icon 1210

Table of Contents