Download Print this page

Lava Aire Aviator X2 Instruction Manual page 15

Electric commercial grade patio cooler
Hide thumbs Also See for Aviator X2:

Advertisement

@2012.11-V1.1
Thoroughly Cleaning ( Suitable for cleaning after 60 hours' operation)
²
1.
Take the main body apart with the water tank.
1.1 Loosen the 4 butterfly screws on the plate inside the tank
(Refer to the Installation Instruction—Step 3 / Picture 4)
1.2 Take the main body apart with the water tank; take out the submersible pump
and water level sensor (Refer to Installation Instruction—Step 2 / Picture 2)
2.
Clean the water tank
Wash the Water Tank inwall with towels or soft brush; open the drain valve
to drain off the waste water; then wash it again with fresh water and the right
amount of cleanser; close the drain valve.
3、Refix the submersible pump and water level sensor; Connect the main body with
the water tank. (Refer to the Installation Instruction—Step 2 / Picture 3)
Note: Please make sure the floater should face the bottom. Otherwise the Level
Sensor will not work.
1、Make sure the machine is connect to the Electricity Leakage protector, and the
earthing wire is connected to specified earthing system of the construction.
2、Before running the product, please check if there any damage or jamming with the
Guard Nets, or if the Impeller rotates smoothly.
3、Pay attention to waterproof and damp-proof.
4、When the Misting Air Cooler is not in the need of using for a long time,
5、4.1 Power should be cut.
6、4.2 The Guard Net, Impeller and body should be clean regularly.
7、4.3 Use specialized protective cover to prevent the damage of rain and dust.