Aiphone AX Quikstart Manual page 3

Hide thumbs Also See for AX:
Table of Contents

Advertisement

3) Door Station
Step 1: Fill in location name of each
door station if desired. (Not required.
Names are not stored in the CEU)
Step 2: Select Video, Audio, or None
depending on which type of door station
is connected to each input. (If setting re-
mains on Video when an audio-only door
station is used, the AX-8MV's LCD will
display a snowy picture when that station
is active.)
Step 3: Set the call priority level by
selecting Priority or Normal from the Call
Level tab. Priority level calls will have a
faster call tone and flashing LED on the
master.
Step 4: Set the door release contact to
either Normally Open or Normally Closed
by selecting N.O. (Normally Open) or N.C.
(Normally Closed) on the DR Relay tab.
The default is N.O.
Step 5: Enable or disable each station
for being eligible for scanning by
selecting Enable or Disable from the
Scan Monitor Tab.
Step 6: Select if you want the door
station's call tone to ring on each
master station by selecting On or Off
from the Call Tone tab. Please note
that when set to "Off", the LED and
monitor will still come on at the master
when the door calls in. Only the call
tone will be muted.