Mitsubishi Electric MU-A08VD-P1 Service Manual page 14

Split-type, air conditioner/ wireless type models
Hide thumbs Also See for MU-A08VD-P1:
Table of Contents

Advertisement

9-2.
MU-A13VD -
OUTDOOR UNIT
OPERATING PROCEDURE
1. Removing the cabinet
(1) Remove the screws fixing the top panel. (See Photo 2 and
3.)
(2) Remove the top panel. (See Photo 3.)
(3) Remove the screw fixing the service panel. (See Photo 3.)
(4) Pull down the service panel and remove it. (See Photo 3.)
(5) Remove the screws fixing the cabinet.
(6) Remove the cabinet.
(7) Disconnect the indoor/outdoor connecting wire.
(8) Remove the screws fixing the back panel.
(9) Remove the back panel.
Photo 3
Screw of the
cabinet
2. Removing the electrical parts
(1) Remove the service panel and the cabinet. (Refer to 1.)
(2) Remove the following parts.
•Compressor capacitor (C1)
•Outdoor fan capacitor (C2)
•Terminal block (TB)
P1
Screws of the
top panel
Service
panel
Screw of the
service panel
Photo 1
Screws of the front panel and motor support
Photo 2
Direction
to remove
Hooks
Photo 4
Connector
Outdoor
fan
capacitor
(C2)
14
PHOTOS
Screws of the cabinet
Compressor
capacitor (C1)
Terminal
block (TB)
Screws of
the top panel
Screws of
the cabinet

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mu-a10vd-p1Mu-a13vd-p1

Table of Contents