VARIOUS SETTING (MENU/Tools)

Initialization (Tools/Default Setting)

1. Choose initialization (Default Setting) with a shift key in the top screen (Select Tools). An initialization
screen is indicated when a menu button (MENU) is pressed and made to indicate a menu window and
OK is chosen and an enter key (ENTER) is pressed. Each parameter is set up under this condition.
(Each parameter is the condition of the initial value on this screen.)
1
2
1
1
3
2
3
4
4
5
5
6
6
2.After setting, press the menu button (MENU), select "OK" and press the enter key (ENTER). The
setting is memorized.
Note: When the interface board of the option is installed on the product, the function of 2 to 4 of each
following parameter setting range is used. Contact our sales representative or agent at the time of
installation of the optional parts.
Each parameter setting range:
1. LCD Back Color : Setup of the back light (1. Blue 2. White) (Factory setting is 1.Blue at the factory.)
2. DAQ Speed: The interface board of the option is attached, and it is the communication speed when it
is connected with the DAQ system and so on. It can be set up in 0(2400bps), 1(4800bps) and 2.
(9600bps). Though a display screen is the indication of 0 and 2. But it can be set in 1. Usually, set up
0 (2400bps). It is the DAQ standard command mode. (Factory setting is 0(2400bps).)
3. DAQ ID: Select any ID between 1 and 250 when an optional interface beard is attached. At this time,
never overlap. (Factory setting is 0.)
4. DAQ Mode: The setting of change from PC side is impossible when 0 "Local" is selected. The
temperature change on "Temp. Setting" screen is impossible and "Remote" is displayed on the upper
right of "Temp. Setting" screen when 1 "Remote" is selected. The DAQ mode is effective when DAQ
speed is 0 "2400" or 2 "9600" When 1 is chosen, "Remote" is highlighted at the upper right of the Temp.
Setting screen.
5. Remote Alarm: ON-off of the remote alarm contact can be set up at the time of the alarm. (Factory
setting is 1.)
6. Control: 0. Normal (Normal) is the mode of the normal operation.
Eco-mode (ECO) is the mode which it drives in with saving energy without using the operation of the
compressor as much as possible. A state of operation is indicated in the column of Control of the Temp.
Setting screen.
(ECO) in the year on saving energy.
Note: The period of temperature of the chamber may become irregular in case of the eco-mode (ECO).
The normal mode (Normal) is recommended when a temperature recorder is installed on this product.
3 4
5
6
7 8
9
0
1 2
3
4 5
D e f a u l t
S e t t i n g
L C D
B a c k
C o l o r
D A Q
S p e e d
D A Q
I D
D A Q
M o d e
R e m o t e
A l a r m
C o n t r o l
When it is compared with the normal mode, about 5% is effective in the eco-mode
6
7 8
9
0 1
2
3
4 5
6 7
1
( 1 . B l u e
0
( 0 . 2 4 0 0
0
( 0 . O F F
0
( 0 . L o c a l
1
( 0 . O F F
0
( 0 . N o r m a l
27
8
9
0 1
2
3 4
5
6
7
8 9
2 . Wh i t e )
2 . 9 6 0 0 )
1 - 2 5 0 )
1 . R e m o t e )
1 . A c t i v e )
1 . E C O )
(Factory setting is 0.)
0
1.