Flowmeter; Inlet Valve - Midea WQP6-3305E series Technical Service Manual

Compact dishwasher ?6 settings?
Table of Contents

Advertisement

3.
Pull out check plate from check plate holder, and replace a new check plate.
4.
Reverse the above procedure to install. And check out all connectors connects well.

Flowmeter

Flowmeter is an instrument for monitoring, measuring the rate of flow. Main
board control inlet valve to be on / off according signal of flowmeter.
Removal and Installation
1.
Take off cutlery basket, basket and filter system.
2.
Remove shell. (see shell removal and installation)
3.
Take out two corner boards, absorber sound, backboard, hollow plate.
4.
Remove tank assembly. (see tank assembly removal and installation)
5.
Take out plug housing for male terminal. Remove all clamps for fixing
connecting hose to flowmeter.
Clamps
Plug housing
6.
Reverse the above procedure to install. And check out all connectors connects well.

Inlet valve

Removal and Replacement
1.
Take off cutlery basket, basket and filter system.
2.
Remove shell. (see shell removal and installation)
3.
Take out two corner boards, absorber sound,
backboard, hollow plate.
4.
Remove tank assembly. (see tank assembly removal
and installation)
5.
Remove two locking terminals for connecting inlet
valve. Then take out Inlet valve block for inlet valve,
and then take out inlet valve. Remove clamp for fixing connecting hose to inlet valve.
Clamp
Locking terminals
Part name: 1 – Inlet valve block
 
1
control