Command List
Only the following functions are supported while the projector is turned off. Do not try to send any
other command to the projector.
Power on/off: Read
Power on: Write
Get light time: Read
Input of a valid signal must be in progress in order to use a command to turn on blank screen or
change the aspect ratio.
Power On/Off:
Input Switching: 0: Switches the input source to the
COMPUTER terminal and changes the
COMPUTER terminal setting to RGB.
1: Switches the input source to COMPUTER
terminal and changes the COMPUTER
terminal setting to component.
6: Switches the input source to COMPUTER
terminal and changes the COMPUTER
terminal setting to Auto.
7: Switches the input source to HDMI.
Blank Screen: Switches the blank screen on or off.
Volume: Specifies a value to adjust the volume level. This
setting is applied to the input source signal that is
currently being projected by the projector.
Color Mode: Selects the color mode.
Aspect Ratio: Specifies the aspect ratio.
Get Light Time: Gets the light time from the projector.
Eco Mode: Enter Eco Mode.
Freeze: Switches freeze on or off.
Keystone Correction:
Specifies the keystone correction setting as a value that
corresponds to the typical Setup Menu "Keystone
Correction" settings below.
0: Keystone Correction –60
60: Keystone Correction 0
120: Keystone Correction +60
Example: 65 here, specifies a setting equivalent to
Keystone Correction +5.
Function
R: Read enabled W: Write enabled
Command
RW
Name
PWR
RW
SRC
RW
BLK
RW
VOL
RW
PST
RW
ARZ
RW
LMP
R
PMD
RW
FRZ
RW
KST
RW
41
Setting Range
0: Off, 1: On
0: RGB, 1: Component,
6: Auto (RGB/Component),
7: HDMI
0: Off, 1: On
0 to 30
1: Graphics, 2: Theater,
3: Standard, 4: Blackboard,
5: Natural
0: Normal, 1: 16:9, 4: Full,
7: 16:10 (when RGB or HDMI
(PC) is selected for input)
1: 16:9, 2: Normal, 6: 4:3,
7: 16:10 (when Component or
HDMI (DTV) is selected for
input)
0- Unit: Hours
0: Off (Bright), 1: Off (Normal),
3: On (Manual 1),
4: On (Manual 2),
5: On (Manual 3),
6: On (Manual 4),
7: On (Manual 5)
0: Off, 1: On
0 to 120