INSTALLATION SITE INSTRUCTIONS
Outdoor Unit
Select a site that allows for the following:
1. Outdoor location meets all minimum installation clearances defined below.
2. Sound from outdoor unit will not annoy neighbors.
3. All connections can be easily made to indoor unit.
4. Air inlet and outlet will be clear of obstructions to ensure proper airflow.
5. Wall or roof is strong enough to withstand the full weight and vibration of the outdoor
unit (for wall or roof installation only).
6. Outdoor unit is out of reach of children and does not obstruct walkways.
7. Outdoor unit is not exposed to direct sunlight, excessive dust or strong wind.
8. Condensate water can drain freely during heating
9. Maintenance and repairs can be easily performed on the outdoor unit.
10. Ensure the installation complies with the minimum and maximum connecting piping
length and maximum change in elevation as defined in the System Requirements section.
Minimum Outdoor Clearances
B
Outdoor Unit
A
B
C
D
E
C
D
Air outlet
Minimum Distances
in (mm)
20 (500)
12 (305)
20 (500)
24 (610)
12 (305)
Air inlet
E
9