PREPARATION BEFORE OPERATION

I Indoor Unit

1
Connect the power supply cord to an independent
power supply.

HOW TO OPERATE

3
2
I To start the operation
• Press 1.
• POWER indicator (green) on the indoor unit will light up.
• To stop, press once more.
I Setting Mode
• Press 2 to select:-
Cooling Model
AUTO
– Automatic Operation
COOL
– Cooling Operation
DRY
– Soft Dry Operation
FAN
– Air Circulation Operation
Heat Pump Model
AUTO
– Automatic Operation
HEAT
– Heating Operation
COOL
– Cooling Operation
DRY
– Soft Dry Operation
5
I Setting Temperature
• Press 3 to increase or decrease the temperature.
• The temperature can be set between 16°C ~ 30°C
• Recommended temperature:
1
Cooling Model
COOL –> 26°C ~ 28°C
DRY
–> 1°C ~ 2°C
lower than the
room temperature
• During AUTO Operation, press 3 to select:-
• Operation with 2°C higher than the standard
• Operation with the standard temperature.
• Operation with 2°C lower than the standard
G Standard Temperature
1
4
6
Indoor
5
temperature
23°C
• Once the Automatic Operation is selected, the indoor
temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.
• After the operation mode has been selected, the
mode does not change.
Indoor
temperature
23°C
20°C
• At the beginning of the automatic operation, Heating,
Cooling or Soft Dry is automatically selected according
to the indoor temperature.
• After the operation mode has been selected, the
mode does not change.
Heat Pump Model
COOL –> 26°C ~ 28°C
DRY
–> 1°C ~ 2°C
lower than the
room temperature
HEAT –> 20°C ~ 24°C
temperature.
temperature.
Cooling Model
Standard
Operation
temperature
Cooling
25°C
Soft Dry
22°C
Heat Pump Model
Standard
Operation
temperature
Cooling
25°C
Soft Dry
22°C
Heating
21°C
G Operation Details
COOL – Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO – Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY – Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low Fan Speed.
HEAT – Heating Operation
(for Heat Pump Model only)
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN – Air Circulation Operation
(for Cooling Model only)
Heated air rises and collects at the top of the room.
The air circulation circulates the heated air downward,
thus increasing heating effectiveness. When the unit
is installed floor mounted, you should set the
temperature higher than that of ceiling mounted.
At ceiling mounted