Safety • Always place the machine in the water before connecting it to the electrical supply. • Always connect the power supply to an approved GFCI, ground fault circuit interrupter. • Do not handle machine while it is plugged into the electrical supply. •...
Filter Removal Step 1: Press Dome Button Step 2: Lift to remove Filter to lift Dome for filter removal. Bucket Housing. Filter cartridge removed Filter Bucket Housing Page 4...
Page 7
Filter Removal Step 3: Open filter doors by unsnapping Step 4: Lift filter cartridges out. and lifting up both filter door latches. Spring cleanup filter elements. For temporary use in heavy spring cleaning. Note: Elements can be cleaned by gently spraying with a garden hose.
Page 8
Filter Replacement Hold both cartridges toward center. Push down cover and press tab towards fan to lock cartridges in place. Make sure cover snaps in place. Page 6...
Wheel and Tire Removal Step 1: Remove wheel axle plug from wheel. Note: During re-assembly, reinstall wheels to Side Covers before reinstalling Step 2: Remove wheel from wheel bushing and cleaner base. sides to Cleaner Base. Page 7...
Side Cover Removal Step 3: Remove Wheel Step 1: Remove T20 screw Step 2: Remove black cover Shield by unsnapping and Wheel Drive Gear. and idler gear. tabs from Side Cover. Step 4: Remove snap With Cover Removed retainers by unsnapping tabs from Side Cover.
Drive Track & Pulley Bearing Removal Drive Side Check for missing/broken drive Pulley Bearings cogs on inner loop of belt and also for cracks in belt. Bearings should rotate smoothly and freely. Note that flange faces inward. Page 9...
Drive Shaft Pulley Removal Note drive ‘key’ in pulley and how it mates to the output Drive Shaft Pulley, motor output side only. shaft drive pin of the motor. Remove by pulling away from Cleaner Base. Page 10...
Wheel Tube Brush Removal Replacement Start in the center of the brush and put Brush replacement can be done with the post through the hole in the tab the cleaner assembled or broken with the aid of a pair of needle nose down.
Power Cord Removal Plate removed showing Step 1: Remove Cord Step 2: Remove strain relief strain relief system. Assembly holder from cover plate. Right Side Cover. Threaded plug removed Step 3: Use Spanner Wrench and Torque driver to remove threaded plug. Page 13...
Page 16
Power Cord Installation Note: Connector must be installed with tab Note the order of the seals and on connector placed in mating hole of washers. Remember to mate the motor assembly. taper of the seal to the threaded plug. Step 1: Before and after inserting Step 2: Use the Torque driver and cord, apply RTV 162 Sealant to spanner wrench to install the threaded...
Motor Box Removal Remove 4 T20 screws securing motor to base. When removing motor assembly without complete removal of side cover, gently separate motor output shaft from keyed drive gear using a screwdriver. The drive gear will remain in place. Be sure to remove all 4 motor securing screws.
Motor Box Removal Rotate motor slightly to remove drive output shaft Output shaft key on motor, mates from side of unit, then lift out motor assembly. with drive gear. Note: The motor assembly is a sealed unit and cannot be serviced, only replaced. It does not Impeller removal contain oil and is water cooled.
Testing Power Supply Note: Make sure the Power Supply is plugged in and on prior to proceeding. If power LEDs are pulsing, the output voltage is disabled on the power supply. You must press the power button and wait for the power LEDs to light up solid before taking the voltage measurement Step 1: Set the multimeter to measure DC volts.
Page 20
Flotation Cord / Motor box Testing If the voltage is more than 0.1VDC, there is likely water in the Cord or Motor Assembly. Continue to Step 3. Step 1: Set the multimeter Step 2: With the floatation cord to measure DC volts. disconnected from the power supply for at least 30 seconds, measure the voltage on the floatation connector pins.
Troubleshooting Startup • Machine will sequence between pump and drive motor for up to 1 minute. • During this time the microprocessor is sampling motors for proper electrical load. Mapping Sequence • At about 2 minutes the machine will begin mapping the immediate section of the pool. •...
Page 22
Troubleshooting Navigation • The unit navigates itself primarily by running in a diagonal direction at the water line. • This is the key to complete pool coverage. Shutdown • The power supply will continue to supply low voltage to the unit and the diagnostic memory will continue to record hours until the power switch is turned off.
Page 23
Troubleshooting Runs only a few seconds or minutes • Make sure the machine is submerged in the water. An out of water detection within a few minutes will cause the machine to stop if not completely submerged. • Check electrical source for proper voltage. •...
Page 24
Troubleshooting No movement but impeller turns • Drive motor pin or drive motor is broken possible due to overload during use. To avoid repeat failure, follow-up with the customer for obstructions in the pool such as a ladder. • Check for belt or roller obstruction •...
Page 25
Troubleshooting Debris falls from unit when removed from pool • Filter overload, increase frequency of filter cleaning. • Large debris blocking intake. Remove large debris from pool before using machine. • Drain flaps out of place on bottom lid. Snap flaps back into place. Page 23...