DCR-TRV738E/TRV740/TRV740E/TRV840
Self-diagnosis Code
Block
Detailed
Function
Code
E
6
1
0
E
6
1
1
E
6
2
0
E
6
2
0
Symptom/State
Difficult to adjust focus
0
(Cannot initialize focus.)
Zoom operations fault
0
(Cannot initialize zoom lens.)
Handshake correction function does not
0
work well. (With pitch angular velocity
sensor output stopped.)
Handshake correction function does not
1
work well. (With yaw angular velocity
sensor output stopped.)
Inspect the lens block focus reset sensor (Pin qs of CN1551 of
VC-278 board) when focusing is performed when the focus ring is
rotated in the focus manual mode and the focus motor drive circuit
(IC1555 of VC-278 board) when the focusing is not performed.
Inspect the lens block zoom reset sensor (Pin qa of CN1551 of
VC-278 board) when zooming is performed when the zoom switch
is operated and the zoom motor drive circuit (IC1555 of VC-278
board) when zooming is not performed.
Inspect pitch angular velocity sensor (SE301 of SE-032 board)
peripheral circuits.