Self-Diagnosis Function; Self-Diagnosis Display; Service Mode Display - Sony DCR-TRV738E Service Manual

Hide thumbs Also See for DCR-TRV738E:
Table of Contents

Advertisement

DCR-TRV738E/TRV740/TRV740E/TRV840

1-2. SELF-DIAGNOSIS FUNCTION

1.
Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder or Display
window what to do. This function consists of two display; self-
diagnosis display and service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
Viewfinder
C : 3 1 : 1 1
Repaired by:
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
3.

Service Mode Display

The service mode display shows up to six self-diagnosis codes shown in the past.
3-1.
Display Method
While pressing the "STOP" key, set the switch from OFF to "VTR or PLAYER", and continue pressing the "STOP" key for 5 seconds
continuously. The service mode will be displayed, and the counter will show the backup No. and the 5-character self-diagnosis codes.
Viewfinder
[3] C : 3 1 : 1 1
Backup No.
Order of previous errors
3-2.
Switching of Backup No.
By rotating the control dial, past self-diagnosis codes will be shown in order. The backup No. in the [] indicates the order in which the
problem occurred. (If the number of problems which occurred is less than 6, only the number of problems which occurred will be shown.)
[1] : Occurred first time
[2] : Occurred second time
[3] : Occurred third time
3-3.
End of Display
Turning OFF the power supply will end the service mode display.
Note: The "self-diagnosis display" data will be kept even if lithium battery (CF-2500 block BT001 of cabinet (R) assembly) is
removed.
Blinks at 3.2Hz
1 1
C
3 1
Block
Indicates the appropriate
Refer to page 1-3 and 1-4.
Self-diagnosis Code Table.
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Display window
3 C : 3 1 : 11
Lights up
[3]
C : 3 1 : 1 1
Self-diagnosis Codes
[4] : Occurred fourth time
[5] : Occurred fifth time
[6] : Occurred the last time
2.

Self-diagnosis Display

When problems occur while the unit is operating, the counter of the
viewfinder or Display window shows a 4-digit display consisting
of an alphabet and numbers, which blinks at 3.2 Hz. This 5-character
display indicates the "repaired by:", "block" in which the problem
occurred, and "detailed code" of the problem.
Display window
C : 3 1 : 11
Detailed Code
Control dial
1-2
Display window

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dcr-trv740Trv740eTrv840

Table of Contents