Step 7 Attach 10P FFC at the connector (FP8251) on the Main
P.C.B..
Step 8 Attch 24P FFC at the connector (FP8201) on the Main
P.C.B..
Step 9 Attach 2P Wire at a connector (CN2007) on the Main
P.C.B..
Step 10 Attach 13P Cable at the connector (CN5802) on the
SMPS P.C.B..
Step 11 Positioned the Front Panel Unit as shown.
Step 12 Detach 30P FFC at the connector (CN2004) on the
Main P.C.B..
Step 13 Side B Main P.C.B. can be checked at diagram shown.

11.4. Checking of SMPS P.C.B.

Step 1 Remove Top Cabinet.
Step 2 Remove Front Panel Unit.
Step 3 Remove SMPS P.C.B. and Voltage Selector P.C.B..
Step 4 Place the Front Panel Unit as diagram shown.
Step 5 Attach 30P FFC to the connector (CN2004) on the Main
P.C.B..
Step 6 Place the SMPS P.C.B. and Voltage Selector P.C.B. on
the insulated material.
Step 7 Attach 13P Cable to the connector (CN5802) on the
SMPS P.C.B..
Step 8 SMPS P.C.B. can be checked as diagram shown.