Initialization Pulse Adjust - Panasonic TH-37PR11UK Service Manual

High definition hospitality plasma display
Hide thumbs Also See for TH-37PR11UK:
Table of Contents

Advertisement

TH-37PR11UK / TH-37PR11UH
9.1.2.

Initialization Pulse Adjust

1. Set Aging pattern (white pattern signal) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TPSC1 and adjust VR6602 for 210 ± 10V.
TPSC1 (SC)
9.1.3.
P.C.B. (Print Circuit Board) exchange
9.1.3.1.
Caution
1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.
9.1.3.2.
Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
P.C.B.
P Board
Vsus
PFC
SC Board
Vad
SS Board
Ve
D, DS, DN Board
White balance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
DN Board
Set Market Select Number to correct destination by MS mode. (See chap. 6.1.4)
*See the Panel Label.
Caution
Absolutely do not reduce Vsus voltage below Ve not to damage the P.C.B.
Test Point
Volume
VR6602 (SC)
210 ± 10V
at 100
Name
Test Point
TPVSUS (SS)
C446 (+) (-) (P)
TPVAD (SC)
TPVE (SS)
Level
µs
period on the down slope.
Voltage
Volume
Vsus ± 2V
R628 (P)
396V ± 0.5V
R443 (P)
-149V ± 1V
VR6600 (SC)
Ve ± 1V
VR6000 (SS)
28
Remarks
*
*

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Th-37pr11uh

Table of Contents