Ms Mode; Id Mode - Panasonic TH-37PR11UK Service Manual

High definition hospitality plasma display
Hide thumbs Also See for TH-37PR11UK:
Table of Contents

Advertisement

6.1.4.

MS mode

Select the MS mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
To exit the MS mode, press the R button on the remote control.
Caution:
Market Select should be set after exchange of DN-Board.
Destination number
Number
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
6.1.5.

ID mode

Select the ID mode by Up/Down button on the remote control at the front page of CAT mode and then press the Mute button on
the remote control more than 3 seconds.
To exit the ID mode, press the R button on the remote control.
Destination
Japan
North America
Europe
Others
Britain
Taiwan
Thailand
--
Japan (Hotel)
North America (Hotel)
Europe (Hotel)
--
Britain (Hotel)
--
Thailand (Hotel)
--
Default setting
Number
Destination
1
North America
13
TH-37PR11UK / TH-37PR11UH
Number
Destination
16
--
17
--
18
China
19
China (Hotel)
20
Russia
21
Russia (Hotel)
22
Hong Kong
23
--
24
--
25
--
26
--
27
--
28
Middle East/Hong Kong
29
Middle East/Hong Kong (Hotel)
30
Australia
31
Australia (Hotel)