Initialization Pulse Adjust; Printed Circuit Board) Exchange - Panasonic TH-58PH10EK Service Manual

High definition plasma display gph10d chassis
Hide thumbs Also See for TH-58PH10EK:
Table of Contents

Advertisement

TH-58PH10BK / TH-58PH10EK
8.2.

Initialization Pulse Adjust

1. Set Aging pattern 0 (Vset adjustment pattern) by IIC mode.
2. Set the picture controls as follows.
Picture menu: Standard
Picture: +25
Aspect: Full
3. Connect Oscilloscope to TPSC1 (T2) and adjust VR6602 for 185±10µ Sec.
8.3.
P.C.B. (Printed Circuit Board) exchange
8.3.1.
Caution
1. To remove P.C.B., wait 1 minute after power was off for discharge from electrolysis capacitors.
8.3.2.
Quick adjustment after P.C.B. exchange
Adjust the following voltages with the multimeter.
P.C.B.
P Board
Vsus
SC Board
Vad
Vbk
SS Board
Ve
D, DS, DN Board
White balance, Pedestal and Sub brightness for NTSC, PAL, HD, PC and 625i signals
DN Board
Set Market Select Number to correct destination by MS mode. (See chap. 9.1.4)
*See the Panel label.
Caution:
Absolutely do not reduce Vsus voltage below Ve not to damage the P.C.B.
Test point
T2
TPSC1 (SC)
VR6602 (SC)
Name
Test Point
TPVSUS (SS)
TPVAD (SC)
TPVBK (SC)
TPVE (SS)
Volume
Level
185 ± 10µ Sec.
Voltage
Volume
Vsus ± 2V
VR251 (P)
-100V ± 1V
VR6600 (SC)
155V ± 1V
VR6604 (SC)
Ve ± 1V
VR6000 (SS)
22
Remarks
*
*