The SAVE VTR150 is a heat recovery ventilation unit with a built in rotating highly efficient heat exchanger and cooker hood. The SAVE VTR 150/K is suitable for smaller flats or houses. It supplies filtered outdoor air to residential areas and extract air from bathroom, kitchen and wet rooms.
Confirm menu choices or settings by pressing the button Back button Step back in the menu levels and to abort an initiated parameter change and restore the original value by pressing the button. SAVE VTR 150/K User Manual Systemair AB 207997...
5.1 Start up wizard The Start up Wizard is a step-by-step configuration tool that starts automatically when the VTR 150/K is started for the first time or when: • a factory reset is performed SAVE VTR 150/K User Manual Systemair AB 207997...
The filter type is labelled on the top of the filter. 7. Here it is possible to change the Airflow l/s EF SF Nominal/High/Low air flow on the Exhaust and Supply air fans. When settings are done, press confirm. SAVE VTR 150/K User Manual Systemair AB 207997...
4 steps: Off, Low, Nom and High. By doing so, you override the programmed week schedule for the unit until the end of the present time period in the week program. SAVE VTR 150/K User Manual Systemair AB...
3 minutes, to prevent the heater from triggering the over heat protection sensor, before they stop. 8. Step back with the Back button until you reach the main menu display SAVE VTR 150/K User Manual Systemair AB 207997...
6.2 Changing halogen lamps Warning The lamps may be hot! Risk of burn injuries. Switch off the power and let the lamps cool down. Pull down the metal ring securing the lamp glass. SAVE VTR 150/K User Manual Systemair AB 207997...
7.2 Remove / mount the outer front The outer front is mounted with four pins and is removed by pulling it towards you. To re-mount the outer front, place the front on the cooker hood and push it forward. SAVE VTR 150/K User Manual Systemair AB...
New sets of filters can be acquired from your installer or wholesaler. Filter quality F7 can be installed for supply air filtering. The filter type is labelled on the top of the filter. SAVE VTR 150/K User Manual Systemair AB...
3. Clean the fans with a cloth or a soft brush. Do not use water. White spirit can be used to remove obstinate deposits. Allow the fans to dry properly before remounting. 4. Remount the fans. Don’t forget to reconnect the fan power cables. SAVE VTR 150/K User Manual Systemair AB 207997...
Leaves and pollution could plug up the air intake grille (figure 9) and reduce the capacity. Check the air intake grille, and clean as necessary. It is recommended to do this at least twice a year. Fig. 11 Intake grill SAVE VTR 150/K User Manual Systemair AB...
Fig. 12 Cleaning duct system 9 Trouble shooting A warning triangle with text in the display indicates an alarm. Turn menu selector to the warning triangle and press confirm twice to view the alarm. SAVE VTR 150/K User Manual Systemair AB 207997...
Contact your installation company or place of purchase. Filter The alarm is displayed in the Time for filter change. control panel. Change filter according to the instructions in chapter 5.3. SAVE VTR 150/K User Manual Systemair AB 207997...
Page 19
SAVE VTR 150/K User Manual Systemair AB 207997...
Page 20
Systemair AB reserves the right to make changes and improvements to the contents of this manual without prior notice. Systemair AB Industrivägen 3 SE-739 30 Skinnskatteberg, Sweden Phone +46 222 440 00 Fax +46 222 440 99 www.systemair.com 207997...