Adjustment And Replacement; A Djust The Size Of Ice Cube - Orien FS-260IM Service Manual

Automatic ice maker
Hide thumbs Also See for FS-260IM:
Table of Contents

Advertisement

The ambient
and water
temperature
Ice cubes size
The
Hot gas valve
evaporator
is hot more
than 4
Refrigerant
minutes
Electric control
box

Adjustment and Replacement

Replace Control box, fuse and the sensor of temperature
Remove the rear cover, front panel,
Locate the Electronic control box,
Pull out the sensors of temperature (one at the evaporator, another at the condenser).
loosen the screws of rooting the Electronic controller, replace a new one. Reverse the above step
to replace.
If you need replace the fuse, open the front panel of the control box, you will find the figure.
According the figure, take out the fuse, rep
Reverse the above step to reassemble.
If you need replace the sensors of temperature, pull out the sensor of temperature, open the panel
of the controller box, pull out the other side, replace a new one. Reverse the above step to
reassemble.
Adj
ust the size of ice cube
The cube size should only be adj
adjusted, Try to adjust the cubes size when the ice maker is work in the Ice Harvest Status.
1. Power off the icemaker.
The ambient and water
temperature is too low
The size is too big.
The lines of the hot gas
valve loose.
Hot gas valve
performance poor or
break
Refrigerant leaks
The electric control box
is wrong
ELECTRICAL SHOCK HAZARD
Disconnect Electrical Power Before
Beginning Removal of Parts
usted to bring the cubes to the correct shape, the overall size can't be
Adjust the temperature.
See "the adjust of ice cube size".
Plug into again
Replace the coil of hot gas valve if
only because of the coil.
Recharge
Check the control box
lace a new one.
12