SPEC
Item
ECM output peak voltage
(B/R, B/W – Ground)
at cranking (loaded)
at 1,500 r/min (loaded)
at 3,500 r/min (loaded)
Pulser coil output peak voltage
(W/R, W/B – B)
at cranking (unloaded)
at cranking (loaded)
at 1,500 r/min (loaded)
at 3,500 r/min (loaded)
Pulser coil resistance
(W/R, W/B – B)
Throttle position sensor
Output voltage
Cooling water temperature
sensor resistance
at 0 °C (32 °F)
at 80 °C (176 °F)
Oil pressure switch
Operating pressure
Fuel control system
Fuel injector resistance
at 21 °C (70 °F)
Starter motor
Type
Output
Cranking time limit
Brushes
Standard length
Wear limit
Commutator
Standard diameter
Wear limit
Mica
Standard undercut
Wear limit
(*)
The figures are for reference only.
2-7
Specifications
Unit
V
V
V
V
V
V
V
(*)
(P – B)
V
kΩ
kΩ
kPa
(kgf/cm
(*)
kW
Second
mm (in)
mm (in)
mm (in)
mm (in)
mm (in)
mm (in)
F80BET
0.8–1.2 at engine idle speed
127.5–166.7 (1.28–1.67, 18.49–24.17)
2
, psi)
Model
F100DET
210
290
290
3.6
3.4
18.2
34.3
459–561
5.21–6.37
0.290–0.354
12.0
Sliding gear
1.40
30
15.5 (0.61)
9.5 (0.37)
29.0 (1.14)
28.0 (1.10)
0.8 (0.03)
0.2 (0.01)
6D93G11

Advertisement