MAINTENANCE

Electric shock hazard can cause injury or death. Before attempting
to perform any service or maintenance on the unit, turn OFF
the electrical power, and check that the fan has stopped.
ACCESS TO INTERNAL COMPONENTS
When checking or replacing any internal component of
the unit eg coil, fan motor, condensate pump, float switch,
the drip tray and volute must be removed.
DISASSEMBLING DRIP TRAY
• Remove the air intake grille and filter.
• Disconnect the display unit
• Disassembly the diffuser panel by removing the four
screws that attach it to the unit.
• Detach the volute by removing its three screws, and the
electrical panel cover.
• The drip tray can be taken apart by removing its three
screws. As shown in the figure.
Coil
1
2
Fan motor
3
Condensate pump
4
Float switch (in option)

AIR DISTRIBUTION

2
1
Louvre position for correct air flow in heating
1
mode.
Louvre position for correct air flow in cooling
2
mode.
IMPORTANT:
Do not try to move the louvres, when
they are connected to a motor.
WARNING
4
3
Volute
Louvres change position to distribute air according to heating
or cooling operation.
• In cooling operation the louvres are positioned to distribute
air outwards from the discharge, which allow airflow close to
the ceiling.
• In heating mode the louvres are repositioned to blow air in a
downward direction. The air should flow towards to the floor to
prevent layers or stationary hot air forming in the upper part of
the room.
Depending on the control, the louvres may be set on intermediate
positions; as well the louvres may be set to move continuously,
sweep mode. (For more information, see the remote control
manual.)
When the Electro-mechanical thermostat is used the louvres
movement is manual, louvres should be positioned manually.