Mboiler Connection Kit - Technibel REVE 247C Service Manual

Hide thumbs Also See for REVE 247C:
Table of Contents

Advertisement

BOILER CONNECTION KIT ONLY FOR MODELS 247C / 237R
M
Existing water
connections
By installer
DISEGNO MACCHINA
1/2" Gas Female
diameter
Electric water
valve
Controller
By installer
1) SPECIFICATIONS
Power source
Capacity at standard conditions
Power input
Fan speed
Standard conditions:
Water coil only
Valve and tubes
including
OPERATING LIMITS
Max temperature inlet hot water
Max pressure
Typical installation
Hot water coil
Ambient temp.
Fan speed
Inlet water temp. °C
∆T water
∆P water
water flow
∆P water
water flow
Boiler connection Kit
W
W
°C
K
kPa
l/h
kPa
l/h
°C
bar
39
Air conditioner
unit
230 V ~ 50 Hz
2100
27
3 ( Hi - Me - Lo )
20
High
70
10
0,7 ( 70 mmH2O)
155 ( 2,6 l/min.)
2,9 ( 290 mmH2O)
190 ( 3,1 l/min.)
70°C
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reve 237r

Table of Contents