Specifications - Grant EUROFLAME 50/70 User, Installation And Servicing Instructions

Grant euroflame kitchen/utility and boiler house models 50/70, 70/90, 90/120 and kitchen/utility system models 50/90, 90/120
Table of Contents

Advertisement

2 - BOILER TECHNICAL INFORMATION
Euroflame oil boilers using Class C2 kerosene
2.2
Note: All boilers are despatched for use with kerosene.
Net efficiency **
Model
Heat Output
(kW)
(Btu/h)
Utility
50/70
14.7
50 000
93.0
Riello RDB
*
17.6
60 000
93.0
20.5
70 000
93.0
70/90
20.5
70 000
93.2
Riello RDB
*
23.5
80 000
93.2
26.4
90 000
93.2
50/90
14.7
50 000
93.2
Riello RDB
17.6
60 000
93.2
20.5
70 000
93.2
*
23.5
80 000
93.2
26.4
90 000
93.2
90/120
26.4
90 000
92.0
Riello RDB2
*
32.2
110 000
92.0
35.2
120 000
92.0
2.3
Euroflame oil boilers using Class D gas oil
Net efficiency **
Model
Heat Output
(kW)
(Btu/h)
Utility
50/70
20.5
70 000
93.0
Riello RDB
70/90
26.4
90 000
93.2
Riello RDB
50/90
26.4
90 000
93.2
Riello RDB
35.2
120 000
92.0
90/120
Riello RDB2
Notes:
1 The data given above is approximate only. The Kerosene table is based on the boiler being used with a low level balanced flue.
2 The above settings may have to be adjusted on site for the correct operation of the burner.
3 Gas Oil is not suitable for use with balanced flue.
4 The installer must amend the boiler data label if the type of fuel or nozzle used is changed.
5 When commissioning, or when the output or fuel is changed, the air damper must be adjusted to obtain the correct CO
6 Boiler House models: When used with a balanced flue, the air intake grille on the burner must be replaced with the air intake
spigot supplied with the flue kit. The air intake hose must be attached to the burner spigot using the clip supplied.
7 50/90 System boiler: It is necessary to adjust the top baffle plate and exchange the burner head when setting the boiler to
50 000 or 60 000 Btu/h output.
8 Net flue gas temperatures given are ± 10%.
9 * Indicates the factory set output.
10 ** Net thermal efficiency (BSRIA).
Net Heat Input
Nozzle
(%)
B/House
(kW)
(Btu/h)
90.0
16.1
54 900
0.50/60°EH
90.0
19.3
65 900
0.60/60°EH
90.0
22.5
76 900
0.60/60°EH
91.8
22.5
76 900
0.60/60°EH
91.8
25.8
87 900
0.75/60°EH
91.8
29.0
98 900
0.75/60°EH
N/A
16.1
54 900
0.50/60°EH
N/A
19.3
65 900
0.60/60°EH
N/A
22.5
76 900
0.60/60°EH
N/A
25.8
87 900
0.75/60°EH
N/A
29.0
98 900
0.75/60°EH
90.9
28.7
96 700
0.75/80°H
35.0
119 400
1.00/80°H
90.9
90.9
38.0
129 600
1.00/80°H
Net Heat Input
Nozzle
(%)
B/House
(kW)
(Btu/h)
90.0
22.5
76 900
0.40/60°S
91.8
29.0
98 900
0.60/60°S
N/A
29.0
98 900
0.60/60°S
90.9
38.2
130 400
0.75/80°S
Euroflame Oil Boilers
Oil
Smoke
Burner
Fuel flow
press.
No.
head
(bar)
7.00
0 - 1
LD2SX short
7.00
0 - 1
LD2SX short
8.50
0 - 1
LD2SX short
8.50
0 - 1
LD3
7.00
0 - 1
LD3
9.50
0 - 1
LD3
7.00
0 - 1
LD2
7.00
0 - 1
LD2
8.50
0 - 1
LD3
7.00
0 - 1
LD3
9.50
0 - 1
LD3
9.50
0 - 1
LD3A
8.00
0 - 1
LD3A
8.60
0 - 1
LD3A
Oil
Smoke
Burner
Fuel flow
press.
No.
head
(bar)
12.00
0 - 1
LD2SX short
12.00
0 - 1
LD3
12.00
0 - 1
LD3
12.50
0 - 1
LD3A
Flue gas
CO
Top
2
rate
temp.
baffle
(kg/h)
(°C)
(%)
position
1.33
211
11.5
N/A
1.60
211
11.5
N/A
1.87
211
11.5
N/A
1.87
180
11.5
Left
2.13
180
11.5
Left
2.40
180
11.5
Left
1.33
180
11.5
Right
1.60
180
11.5
Right
1.87
180
11.5
Left
2.13
180
11.5
Left
2.40
180
11.5
Left
2.38
190
12.0
N/A
2.62
220
12.0
N/A
3.12
225
12.0
N/A
Flue gas
CO
Top
2
rate
temp.
baffle
(kg/h)
(°C)
(%)
position
1.60
200
11.5
N/A
1.97
200
11.5
Left
1.97
200
11.5
Left
3.20
220
12.0
N/A
level.
2
7