3 - GENERAL BOILER INFORMATION
Regulations to comply with
3.2
Installation of a Euroflame boiler must be in
accordance with the following recommendations:-
a Building Regulations for England and Wales, and
the Building Standards for Scotland issued by the
Department of the Environment and any local
Byelaws etc.
b Model and local Water Undertaking Byelaws.
c Applicable Control of Pollution Regulations.
d The following OFTEC requirements:-
OFST 100
Polythene oil storage tanks for
distillate fuels.
OFST 200
Fuel oil storage tanks and tank
bunds for use with distillate fuels,
lubrication oils and waste oils.
Further information may be obtained from the
OFTEC Technical Information Book 3
(Installation requirements for oil fired boilers
and oil storage tanks).
The installation should also be in accordance with the
latest edition of the following British Standard Codes of
Practice:-
BS 715
Metal flue pipes, fittings, terminals and
accessories.
BS 799:5
Oil storage tanks.
BS 1181
Clay flue linings and flue terminals.
BS 4543:3
Factory made insulated chimneys for
oil fired appliances.
BS 4876
Performance requirements for oil
burning appliances.
BS 5410:1
Code of Practice for oil firing appliances.
BS 5449
Forced circulation hot water systems.
BS 7593
Code of Practice for treatment of water
in heating systems.
BS 7671
Requirements for electrical
installations, IEE Wiring Regulations.
Failure to install and commission appliances
correctly may invalidate the boiler warranty.
IMPORTANT
Before starting any work on the boiler, or fuel supply
please read the health and safety information given in
section 11 on page 40.
Regional statutory requirements may deem this appliance to be a 'controlled service'.
Where this is the case, it is a legal requirement that the appliance is installed and
commissioned either under the remit of building control or by a 'Competent person' such
as a suitably qualified Oftec registered technician.
Euroflame Oil Boilers
Delivery
3.3
Kitchen/Utility Conventional flue models are supplied
in one pack, containing the cased boiler with the
burner and control panel fitted, and literature pack.
Kitchen/Utility Balanced flue models are supplied in
two packs, containing the following:-
Carton 1 The cased boiler with burner and control
panel fitted, and literature pack.
Carton 2 The balanced flue kit - low, high level or
vertical, as ordered. A terminal guard is
supplied with a low level flue kit.
Boiler House Conventional flue models are supplied in
two packs, containing the following:-
Carton 1 The boiler with literature pack, but
without burner.
Carton 2 The burner with the combined boiler and
overheat thermostat.
Boiler House Balanced flue models are supplied in
three packs as follows:-
Carton 1 The boiler with literature pack, but
without burner.
Carton 2 The burner with the combined boiler and
overheat thermostat.
Carton 3 The balanced flue kit - low level, high level
or vertical as ordered. A terminal guard is
supplied with a low level flue kit.
The following flue kits are available, refer to section
3.8 for further details.
a Low level concentric balanced flue.
b Low level concentric balanced flue extensions,
225 mm, 450 mm and 675 mm.
c 90° concentric bend.
d High level balanced flue.
e High level balanced flue extensions.
f
Low level balanced flue - square.
(Short, Standard, Long or Extra Long)
g Vertical balanced flue.
h Vertical balanced flue extensions.
i
45° elbows for high level and vertical balanced flues.
11