Installation Diagram Of Indoor And Outdoor Units - Toshiba RAS-12KSX-1 Service Manual

Air conditioner split wall type
Table of Contents

Advertisement

8-2. Installation Diagram of Indoor and Outdoor Units

5
Active-Carbon-
Catechin filter
3
Batteries
7
2
Wireless remote control
Before installing the
wireless remote control
.
With the remote control cover
open, load the batteries supplied
correctly, observing their
polarity.
2
Wireless remote control
3
Batteries
4
Remote control holder
Pan head
wood screw
Vinyl tape
Apply after carrying
out a drainage test.
Remark :
• Detail of accessory and installation parts can
see in the accessory sheet.
Hook
1
Installation
plate
Shield pipe
Saddle
Extension
drain hose
(Not available,
provided by installer)
− 20 −
FILE NO. SVM-08029
For the rear left and left piping
Wall
Insert the cushion between the indoor
unit and wall, and tilt the indoor unit
for better operation.
Do not allow the drain hose to get
slack.
Cut the piping
hole sloped
slightly.
Make sure to run the drain hose
sloped downward.
The auxiliary piping can be connected
to the left, rear left, rear right, right,
bottom right or bottom left.
Right
Rear
right
Rear
Bottom
right
left
Bottom left
Insulate the refrigerant pipes
separately with insulation, not
together.
6 mm thick heat resisting
polyethylene foam
Left