ITEM
Capacity
Power source
Power consumption
Power factor
Running
Indoor
current
Outdoor
Starting current
Moisture removal
Indoor (H/M/L)
Noise
Outdoor (220 - 240 V) dB
Name of refrigerant
Refrigerant
Rated amount
Refrigerant control
Gas side size
Connection type
Liquid side size
Interconnection Connection type
pipe
Maximum length
(One way)
Maximum height
difference
INDOOR UNIT
Height
Dimensions
Width
Depth
Net weight
Evaporator type
Indoor fan type
High fan
Air-flow volume Medium fan
Low fan
Fan motor output
Air filter
OUTDOOR UNIT
Height
Dimensions
Width
Depth
Net weight
Condenser type
Outdoor fan type
Air-flow volume
Fan motor output
Model
Compressor
Output
Safety device
Louver type
Usable outdoor temperature range

1. SPECIFICATIONS

MODEL
kW
Phase
V
Hz
kW
%
A
A
A
lit/h
dB
kg
mm
mm
m
m
mm
mm
mm
kg
m
/h
3
m
/h
3
m
/h
3
W
mm
mm
mm
kg
m
/h
3
W
W
°C
RAS-12SKSX-1 / RAS-12SASX-1
220V
3.58
220 - 240
50
1.27
96
0.15
5.85
23
2.0
44/38/33
48
R22
0.70
Capillary tube
Æ12.7
Flare connection
Æ6.35
Flare connection
10*
15*
6
RAS-12SKSX-1
275
790
205
9
Finned tube
Cross flow fan
590
470
410
20
Honeycomb woven filter with PP frame
RAS-12SASX-1
530
660
240
27
Finned tube
Propeller fan
1590
30
QK222PCB
1100
Fuse, Overload relay
Automatic louver
21 ~ 43
– 2 –
FILE NO. SVM-08029
240 V
3.58
1.31
94
5.65
49
1
2
1710