PRE-FAB ZERO CLEARANCE
The Model 18 may be installed into any UL listed prefabricated fireplace that is large enough to
accept it.
Except for "NOTE(S)", FOLLOW MASONRY INSTALLATION CLEARANCES FOUND
IN YOUR OPERATIONS MANUAL.
Pre-Fab Zero Clearance Fireplace
1. Locate furniture and other materials away from front of fireplace to allow free access to
fireplace.
2. Cover hearth and adjacent floor areas with drop cloths to protect from soiling or marring
surface.
3. Remove existing fireplace damper plate/damper rod assembly.
4. Thoroughly clean fireplace of ashes and soot.
5. Check chimney and smoke chamber for excessive buildup of creosote or soot. Also, check
for obstructions, such as bird's nests. If chimney is excessively dirty, clean it or have
someone clean it professionally BEFORE installing or using the room heater.
6. The Ash Lip, Smoke Baffle and Smoke Shelf may also be removed, if necessary, to provide
room for Model 18. Any other alteration to unit will void ALL New Buck Corporation
responsibility and liability. The WARNING label below must be attached to the back of
fireplace.
WARNING:
restored to its original condition for safe use,
if fireplace insert is removed.
NOTE: Plug power cord into a 115 VAC outlet. Route the cord to prevent damage to cord
insulation from heat and sharp objects. Keep cord out of the way of traffic to prevent damage
caused by tripping, etc.
SECTION III
INSERT INSTALLATION
MINIMUM CLEARANCES
INSTALLATION PREPARATION
This fireplace must be
Page 12