Counter Top / Bar Installation; Brick Panel Installation - Napoleon GVF40P Installation And Operating Instructions Manual

Propane/ natural gas fireplace napoleon gvf40p; gvf40n
Table of Contents

Advertisement

12
3.2

COUNTER TOP / BAR INSTALLATION

When fi nishing the appliance, combustible material may rest
directly on of the top extension.
NOTE: Maximum weight tolerance is 400 lbs, provided
that it is evenly distributed across the top extensions of
the appliance.
In order to achieve a counter top or bar type appearance
with the minimum height allowed, framing must be non-
combustible and may be done with metal studding attached
to the heat shield sides or the upper frame of the appliance.
* The top extension may be removed if non-combustible fram-
ing is faced with a non-combustible material placed fl ush with
the front face of the unit and extending from the top of the unit.
(Example: cement board) (not supplied). Combustible counter /
bar tops must maintain a minimum of 38 inches from the base
of the appliance to the underside of the top.
NOTE: Wolf Steel trim and/or surround kits will
not totally cover the top extension of the appli-
ance. In order to obtain a smooth transition from
the trim / surround to the wall, it is recommended
that the top extension be removed and the unit
be installed following the preceding procedure.
3.3

BRICK PANEL INSTALLATION

Install the base panels as illustrated. The side panel sits under the bracket tab. Holding the side panel in posi-
tion, bend down the tab to secure.
FIGURE 3.3a
FIGURE 3.3d
W415-0810 / 06.11.09
NON-COMBUSTIBLE
MATERIAL *METAL
3"
5"
NONCOMBUSTIBLE
MATERIAL
FIGURE 3.2b
FIGURE 3.3b
RETAINER
FIGURE 3.3e
FIGURE 3.2a
TOP
EXTENSION
*COMBUSTIBLE
STUD
MATERIAL
5"
COMBUSTIBLE
MATERIAL
TOP EXTENTION
TOP OF THE UNIT
FIGURE 3.3c

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gvf40n

Table of Contents