Electrical Connection; Rating Plate - Napoleon GVF40P Installation And Operating Instructions Manual

Propane/ natural gas fireplace napoleon gvf40p; gvf40n
Table of Contents

Advertisement

10
2.4

ELECTRICAL CONNECTION

DO NOT USE THIS HEATER IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SERVICE
TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE
RISK OF ELECTRICAL SHOCK OR EXPLOSION. DO NOT WIRE 110V TO THE VALVE OR TO THE
APPLIANCE WALL SWITCH. INCORRECT WIRING WILL DAMAGE CONTROLS.
ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE
WITH LOCAL CODES. IN THE ABSENCE OF LOCAL CODES, USE THE CURRENT CSA22.1
CANADIAN ELECTRIC CODE IN CANADA OR THE CURRENT NATIONAL ELECTRIC CODE
For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient
location. Route a 2 strand, solid core millivolt wire from the valve to the wall switch or millivolt thermostat. The
recommended maximum lead length depends on wire size:
WIRE SIZE
14 gauge
16 gauge
18 gauge
Disconnect the existing wires from terminals 1 and 3 (from the
ON/OFF switch) and replace with the leads from the wall switch / millivolt thermostat.
2.5

RATING PLATE

THIS APPLIANCE MAY BE INSTALLED IN AN AFTERMARKET,
PERMANENTLY LOCATED, MANUFACTURED (MOBILE) HOME, WHERE
NOT PROHIBITED BY LOCAL CODES. THIS APPLIANCE IS ONLY FOR USE
WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE. THIS
APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES.
WARNING: FIREPLACE SCREENS MUST BE CLOSED WHILE IN OPERATION.
CONTACT WITH THE FLAMES, OTHER THAN THAT SUPPLIED BY THE MANUFACTURER WITH THE APPLIANCE. DO NOT USE BLOWER INSERT, HEAT EXCHANGER INSERT OR OTHER
ACCESSORIES NOT APPROVED FOR USE WITH THIS HEATER. IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTAINANCE CAN CAUSE PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE. REFER TO THE OWNER'S INFORMATION MANUAL PROVIDED WITH THIS APPLIANCE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A
QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER.
MADE IN CANADA
WOLF STEEL LTD, BARRIE, ON, CANADA
For rating plate location, see "DIMENSIONS" section.
W415-0810 / 06.11.09
ELECTRICAL CIRCUIT.
ANSI/NFPA NO. 70 IN THE UNITED STATES.
MAX. LENGTH
100 feet
60 feet
40 feet
CERTIFIED UNDER: ANSI Z21.11.2-2000 VOLUME II, UNVENTED ROOM HEATER
MODEL
GVF40-N / CVF400-N
**0-2000FT (0-610m)
30,000 BTU/h
20,000BTU/h
#39
MANIFOLD PRESSURE: 3.5" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 4.5" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 7.0" WATER COLUMN
SIT CONTROL: #820637
OPERATING PILOT OXYPROTECTOR: # 8214
**
ABOVE 2,000FT, CONSULT LOCAL AUTHORITY HAVING JURISDICTION
NOT FOR USE WITH SOLID FUEL.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS:
TOP / SIDES / BACK / FLOOR
0
RECESSED DEPTH
25¼"
*
MANTLE
5"
WARNING
!
1
2
3
THIS IS A GAS-FIRED UNVENTED ROOM HEATER THAT REQUIRES AD-
EQUATE COMBUSTION AND VENTILATION AIR. THIS UNIT IS NOT APPROVED
FOR BEDROOM, BATHROOM AND BED-SITTING ROOM INSTALLATION.
REFERENCE # W/N 15515
CERTIFIED FOR USA
MODEL
GVF40-P / CVF400-P
ALTITUDE
0-2000FT (0-610m) **
INPUT
28,500 BTU/h
REDUCED INPUT
22,000BTU/h
ORIFICE
#53
MANIFOLD PRESSURE: 10" WATER COLUMN
MINIMUM SUPPLY PRESSURE: 11" WATER COLUMN
MAXIMUM SUPPLY PRESSURE: 13" WATER COLUMN
SIT CONTROL: #820636
OPERATING PILOT OXYPROTECTOR: #8404
DO NOT ADD ANY MATERIAL TO THE APPLIANCE, WHICH WILL COME IN
*
MAXIMUM HORIZONTAL EXTENSION: 2". SEE INSTRUCTION
MANUAL FOR GREATER EXTENSIONS.
ELECTRICAL RATING: 115V 0.82AMP, 60HZ
OPTIONAL FAN KIT: GZ550-KT
SERIAL NUMBER:
50.1
GVF40 / CVF400
W385-0254