Wesmar SS395 Installation & Operation Manual page 33

Table of Contents

Advertisement

above the packing gland.
Adjustment - Move the lower limit switch up on
the hoist rack so the top clamp is 0.5 inch, 13mm
to 1.0 inch, 25.5mm above the packing gland
6. Lift up the soundome - Push the hoist switch up
in the wheelhouse. Touch the wire labeled #27 to
terminal #27. The hoist will start to go up. The
hoist should go up and stop and the motor turn
off.
Adjustment - If the motor keeps running when the
hoist has stopped in the up position the top limit
switch must be lowered. Lower the limit switch
so the hoist will stop 0.5 inch, 13mm before the
mechanical stop.
7. Connect the wires back to terminal #27 and
#1.
2.9.2 Check hoist soundome travel.
1. Lower the soundome, push the hoist switch down
in the wheelhouse.
2. Measure the distance from the bottom of the
seachest to the bottom of the soundome under the
boat. The distance should be 16.5 inch, 42mm to
15.5 inch, 39mm.
2.9.3 Packing gland
1. Tighten the packing gland by rotating the two
nuts hand tight then two complete turns with a
wrench. Tighten the second nut against the first
nut to lock.
2. When the boat is back in the water cycle the hoist
up and down four times. Check the packing gland
for water. It is normal for the packing gland to be
wet but not dripping with water.
3. Retighten the nuts if water drips after cycling
the hoist. WARNING: Do not tighten the packing
gland too tight. A tight packing gland will hold
the soundome tube from moving and may trip the
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents