Pioneer PDR-555RW Service Manual page 48

Compact disc recorder
Hide thumbs Also See for PDR-555RW:
Table of Contents

Advertisement

PDR-555RW, PDR-V500, PDR-19RW, PDR-509
64
: Auto sequence 1-track forward jump repeat
65
: Auto sequence 1-track reverse jump repeat
66
: Auto sequence 10-track forward jump
67
: Auto sequence 10-track reverse jump
68
: (Sound-generating) Scan mode using auto sequence 10-
track forward jump.
69
: (Sound-generating) Scan mode using auto sequence 10-
track reverse jump.
70
: Auto sequence 50-track forward jump
71
: Auto sequence 50-track reverse jump
72
: High-speed scan mode using auto sequence 50-track
forward jump.
73
: High-speed scan mode using auto sequence 50-track reverse
jump.
74
: Several forward jumps in DTRNUM by combining auto
sequence 2N-track jumps
75
: Several reverse jumps in DTRNUM by combining auto
sequence 2N-track jumps
76
: REC mode continuous operation after resuming from a
power failure
78
: Blank search
79
: Resume mode from "tracing error" and "out of focus"
during REC
Errors the Mode Control Generates
Mode : Mode Name
No.
91
: Loading error
C7
: Cannot enter REC/PAUSE of power calibration even when
60 seconds elapsed.
d0
: Stops owing to a resume failure or STOP key input.
d4
: Insufficient data in TOC PMA read
d7
: RF check failure at REC/PAUSE
db
: PMA REC does not finish even when 60 seconds have
elapsed
dd
: Stops owing to a TOC check error or STOP key input
df
: Cannot enter REC/PAUSE even when 60 seconds have
elapsed, cannot start REC even when 10 seconds have
elapsed, or resuming from tracing error does not complete
even when 60 seconds have elapsed
F0
: Communication error of the mechanism control
F1
: Hardware error of the mechanism control: The number of
the defective pin of the mechanical control is displayed at
TRACK.
F2
: A/D input (RFT, RFB) error of the mechanism control
F5
: RID serial number error
48
Two digits displayed for 3 :
Recording submode when the error was
generated
10
: While setting REC/PAUSE
20
: During REC/PAUSE
30
: During REC
40
: While stopping REC
50
: Unlocking, during SCMS stop
Two digits displayed for 4 :
Other condition when the error was
generated is displayed by a HEX code
bit 7
: Out of focus
bit 6
: Sync loss detected during REC
bit 5
: tracing error during REC
bit 4
: TOC read error (insufficient data)
bit 3
: Improper A/D value of RFT, RFB
bit 2
: No meanings
bit 1
: No meanings
bit 0
: No meanings

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rrv2055Pdr-509Pdr-19rw

Table of Contents