NX-320
■ Necessary Deviation adjustment item for each signaling and mode
The following shows the necessary adjustment items for each signaling deviation. Please read the following table like the following example. In the
case of the signaling "QT (Wide 5k)", this signaling is composed of three elements [Balance, Maximum Deviation (Analog Wide 5k) and QT Deviation
(Wide 5k)]. Please adjust Balance and Maximum Deviation (Analog Wide 5k) before adjusting QT Deviation (Wide 5k).
Mode Signaling
Step 1. Balance adjust
Audio
Step 2. Maximum Deviation
(Analog Wide 5k)
Step 1. Balance adjust
Step 2. Maximum Deviation
QT
(Analog Wide 5k)
Step 3. QT Deviation (Wide 5k)
Step 1. Balance adjust
Step 2. Maximum Deviation
DQT
(Analog Wide 5k)
Step 3. DQT Deviation
(Wide 5k)
Step 1. Balance adjust
Step 2. Maximum Deviation
LTR
(Analog Wide 5k)
Step 3. LTR Deviation
Analog
(Wide 5k)
Step 1. Balance adjust
Step 2. Maximum Deviation
DTMF
(Analog Wide 5k)
Step 3. DTMF Deviation
(Wide 5k)
Step 1. Balance adjust
Step 2. Maximum Deviation
5TONE
(Analog Wide 5k)
Step 3. Single Tone Deviation
(Analog Wide 5k)
Step 1. Balance adjust
Step 2. Maximum Deviation
MSK
(Analog Wide 5k)
(FleetSync)
Step 3. MSK Deviation
(Analog Wide 5k)
Audio
NXDN
CW ID
• Balance is common with all the above deviation adjustments. If Balance (Transmitter Section 3) has already adjusted, please skip Step 1 and adjust
from Step 2.
• Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) is common with all the analog signaling deviations and CWID Deviation (NXDN Very Narrow).
If Balance and Maximum Deviation (Analog Wide 5k/Wide 4k/Narrow) (Transmitter Section 5) have already adjusted, please skip Step 2 and adjust
from Step 3.
70
ADJUSTMENT (E TYPE)
Wide 5k
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Wide 4k)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Wide 4k)
Step 3. QT Deviation (Wide 4k)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Wide 4k)
Step 3. DQT Deviation
(Wide 4k)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Wide 4k)
Step 3. LTR Deviation
(Wide 4k)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Wide 4k)
Step 3. DTMF Deviation
(Wide 4k)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Wide 4k)
Step 3. Single Tone Deviation
(Analog Wide 4k)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Wide 4k)
Step 3. MSK Deviation
(Analog Wide 4k)
-
-
Necessary adjustment and order
Wide 4k
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Narrow)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Narrow)
Step 3. QT Deviation (Narrow)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Narrow)
Step 3. DQT Deviation (Narrow)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Narrow)
Step 3. LTR Deviation (Narrow)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Narrow)
Step 3. DTMF Deviation
(Narrow)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Narrow)
Step 3. Single Tone Deviation
(Analog Narrow)
Step 1. Balance adjust
Step 2. Maximum Deviation
(Analog Narrow)
Step 3. MSK Deviation
(Analog Narrow)
Step 1. Balance adjust
Step 2. Maximum Deviation
(NXDN Narrow)
Narrow
Very Narrow
Step 1. Balance adjust
Step 2. Maximum Deviation
(NXDN Very Narrow)
Step 1. Balance adjust
Step 2. Maximun Deviation
-
(Analog Narrow)
Step 3. CW ID Deviation
(NXDN Very Narrow)
-
-
-
-
-
-
-