Panel tuning mode
7. DQT
1) Adj item: [DQT]
Deviation
Adjust: [✳✳✳✳.]
*4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide 4k]
1) Adj item: [DQT]
Adjust: [✳✳✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide 5k]
1) Adj item: [DQT]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
8. LTR
1) Adj item: [LTR]
Deviation
Adjust: [✳✳✳✳.]
*4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide]
1) Adj item: [LTR]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
9. DTMF
1) Adj item: [DTMF]
Deviation
Adjust: [✳✳✳✳.]
*4
Deviation meter
LPF: 15kHz
[Narrow]
HPF: OFF
PTT: ON
Press [B] key to
store the adjust-
ment value.
ADJUSTMENT (E TYPE)
Condition
PC test mode
equipment
1) Adj item: [DQT
Deviation
Deviation (Analog
meter
Narrow)]
Oscilloscope
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [DQT
Deviation (Analog
Wide 4k)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [DQT
Deviation (Analog
Wide 5k)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [LTR
Deviation (Analog
Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [LTR
Deviation (Analog
Wide)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [DTMF
Deviation (Analog
Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
NX-320
Adjustment
Specifi cations /
Parts
Method
[Panel
Write the value as
0.35kHz±0.05kHz
tuning
followings.
mode]
430 (Reference
Selector
value)
[PC test
mode]
[ ],[ ]
0.60kHz±0.05kHz
0.75kHz±0.05kHz
Write the value as
0.75kHz±0.05kHz
followings.
465 (Reference
value)
1.00kHz±0.05kHz
Write the value as
1.25kHz±0.05kHz
followings.
540 (Reference
value)
Remarks