Kenwood NX-320 Series Service Manual page 47

Uhf digital transceiver kenwood nx-320 series
Table of Contents

Advertisement

Item
Panel tuning mode
6. QT
1) Adj item: [QT]
Deviation
Adjust: [✳✳✳✳.]
*4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide]
1) Adj item: [QT]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
7. DQT
1) Adj item: [DQT]
Deviation
Adjust: [✳✳✳✳.]
*4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide]
1) Adj item: [DQT]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
8. LTR
1) Adj item: [LTR]
Deviation
Adjust: [✳✳✳✳.]
*4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide]
1) Adj item: [LTR]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
ADJUSTMENT (K TYPE)
Condition
PC test mode
equipment
1) Adj item: [QT
Deviation
Deviation (Analog
meter
Narrow)]
Oscilloscope
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [QT Devia-
tion (Analog Wide)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [DQT
Deviation (Analog
Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [DQT
Deviation (Analog
Wide)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [LTR
Deviation (Analog
Narrow)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [LTR
Deviation (Analog
Wide)]
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
NX-320
Adjustment
Specifi cations /
Parts
Method
[Panel
Write the value as
0.35kHz±0.05kHz
tuning
followings.
mode]
513 (Reference
Selector
value)
[PC test
mode]
[ ],[ ]
0.75kHz±0.05kHz
Write the value as
0.35kHz±0.05kHz
followings.
430 (Reference
value)
0.75kHz±0.05kHz
Write the value as
0.75kHz±0.05kHz
followings.
465 (Reference
value)
1.00kHz±0.05kHz
Remarks
47

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-320

Table of Contents