Item
Panel tuning mode
Maximum
1) Adj item: [ADEV]
Deviation
Adjust: [✳✳.✳.✳.]
(Analog) *3
2) Adj item: [A.DEV_]→
[A.D.EV_]→[A.D.E.V_]→
[Wide 5k]
[A.D.E.V._]→[A.D.E.V._.]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
*3: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 70.
Regarding Maximum Deviation (Analog), it is common with the adjustment of all analog signalings.
6. QT
1) Adj item: [QT]
Deviation
Adjust: [✳✳✳✳.]
*4
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide 4k]
1) Adj item: [QT]
Adjust: [✳✳✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide 5k]
1) Adj item: [QT]
Adjust: [✳✳.✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
66
ADJUSTMENT (E TYPE)
Condition
PC test mode
equipment
1) Adj item: [Maximum
Deviation
Deviation (Analog
meter
Wide 5k)]
Oscilloscope
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [QT
Deviation
Deviation (Analog
meter
Narrow)]
Oscilloscope
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [QT Devia-
tion (Analog Wide
4k)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
1) Adj item: [QT Devia-
tion (Analog Wide
5k)]
Deviation meter
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply] but-
ton to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
Panel
ANT
Panel
Adjustment
Specifi cations /
Parts
Method
[Panel
4200Hz
4150~4250Hz
tuning
Write the value as
mode]
followings.
[PC test mode]
Selector
513 (Reference
Press [Apply All]
value)
button to store the
[PC test
adjustment value
mode]
after all adjustment
[ ],[ ]
points have been
adjusted.
[Panel
Write the value as
0.35kHz±0.05kHz
tuning
followings.
mode]
513 (Reference
Selector
value)
[PC test
mode]
[ ],[ ]
0.60kHz±0.05kHz
0.75kHz±0.05kHz
Remarks