Item
Panel tuning mode
Maximum
1) Adj item: [NDEV]
Deviation
Adjust: [✳✳✳✳]
(NXDN) *3
2) Adj item: [N.DEV_]→
[N.D.EV_]→[N.D.E.V_]→
[Very
[N.D.E.V._]→[N.D.E.V._.]
Narrow]
Adjust: [✳✳✳✳]
PTT: ON
Press [B] key to
store the adjust-
ment value.
5. Maximum
1) Adj item: [ADEV]
Deviation
Adjust: [✳✳✳✳.]
(Analog) *3
Deviation meter
LPF: 15kHz
[Narrow]
HPF: OFF
2) Adj item: [A.DEV_]→
[A.D.EV_]→[A.D.E.V_]→
[A.D.E.V._]→[A.D.E.V._.]
Adjust: [✳✳✳✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
[Wide 4k]
1) Adj item: [ADEV]
Adjust: [✳✳✳.✳.]
2) Adj item: [A.DEV_]→
[A.D.EV_]→[A.D.E.V_]→
[A.D.E.V._]→[A.D.E.V._.]
Adjust: [✳✳✳.✳.]
PTT: ON
Press [B] key to
store the adjust-
ment value.
ADJUSTMENT (E TYPE)
Condition
PC test mode
equipment
1) Adj item: [Maximum
Deviation
Deviation (NXDN
meter
Very Narrow)]
Oscilloscope
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Maximum
Deviation (Analog
Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Maximum
Deviation (Analog
Wide 4k)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
Measurement
Test-
Unit Terminal Unit
Panel
ANT
Panel
NX-320
Adjustment
Specifi cations /
Parts
Method
[Panel
1337Hz
1311~1363Hz
tuning
Write the value as
mode]
followings.
[PC test mode]
Selector
513 (Reference
Press [Apply All]
value)
button to store the
[PC test
adjustment value
mode]
after all adjustment
[ ],[ ]
points have been
adjusted.
2100Hz
2050~2150Hz
Write the value as
followings.
[PC test mode]
513 (Reference
Press [Apply All]
value)
button to store the
adjustment value
after all adjustment
points have been
adjusted.
3360Hz
3310~3410Hz
Write the value as
followings.
[PC test mode]
513 (Reference
Press [Apply All]
value)
button to store the
adjustment value
after all adjustment
points have been
adjusted.