OPTIONAL POSITIONING
OF THERMOSTAT
SENSING BULB
Continued
4. The mounting clip must be a minimum of 3"
from bottom of fireplace to prevent crimping
of capillary. Once you have decided on a
location, clean the area thoroughly. Remove
the paper backing from the adhesive on back
of mounting clip. Press the clip into the new
location so that the thermostat sensing bulb
will be positioned vertically with the capil-
lary at the bottom (see Figure 47). Slide the
thermostat sensing bulb into the clip.
IMPORTANT: Do not crimp capillary.
Thermostat
Sensing Bulb
Capillary
Figure 47 - Positioning the Thermostat
Sensing Bulb in the Vertical Position
with the Capillary at the Bottom
34
Adhesive-
backed
Mounting Clip
Do Not Crimp
Capillary
www.desatech.com
104415-01M