Desa E18N Owner's Manual page 11

Unvented (vent-free)
Table of Contents

Advertisement

INSTALLATION
Continued
If Using Mantel
You must have noncombustible material(s) above
the fireplace opening. Noncombustible materials
(such as slate, marble, tile, etc.) must be at least
1/2" thick. With sheet metal, you must have non-
combustible material behind it. Noncombustible
material must extend at least 8" up (for all models).
If noncombustible material is less than 12", you
Minimum Non-
Combustible
Material
Figure 6 - Minimum Mantel Clearances Without Using Hood
Minimum Non-
Combustible
Material
Figure 7 - Minimum Mantel Clearances When Using Hood
104415-01M
Mantel Shelf
10"
8"
6"
2
1 /2
"
(A)
12"
18"
20"
8"
14"
17"
Minimum Non-
Distances to
Combustible
Underside of
Material Height
Mantel
12"
10"
8"
6"
1 /2
2
"
8"
12"
Min.
Hood
Hood
Distances to
(GA6050, GA6052)
(GA6050,
Underside of
GA6052, or
Mantel
GA6053)
www.desatech.com
Underside of
Mantel Shelf
All minimum
distances are
in inches
Log Set
22"
24"
24"/30" Models
19"
20"
18" Model
Top of Fireplace
Opening
Underside of
Mantel Shelf
All minimum
distances are
in inches
15"
18"
20"
Top of Fireplace
Opening
Log Sets
18", 24",
& 30" Models
11