Unvented (vent-free)
Table of Contents

Advertisement

2. Inspect burner, pilot, and primary air inlet
holes on injector holder for dust and dirt (see
Figure 39).
3. Blow air through the ports/slots and holes in
the burner.
4. Check the injector holder located at the end
of the burner tube again. Remove any large
particles of dust, dirt, lint, or pet hair with a
soft cloth or vacuum cleaner nozzle.
5. Blow air into the primary air holes on the
injector holder.
6. In case any large clumps of dust have now been
pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot as-
sembly. There is a small pilot air inlet hole about
two inches from where the pilot flame comes out
of the pilot assembly (see Figure 40). With the unit
off, lightly blow air through the air inlet hole. You
may blow through a drinking straw if compressed
air is not available.
Injector Holder
Ports/Slots
Burner Tube
Primary Air Inlet Holes
Figure 39 - Injector Holder On Outlet
Burner Tube
28
Figure 40 - Pilot Inlet Air Hole (Your pilot
www.desatech.com
Pilot Assembly
may vary from pilots shown)
Pilot Assembly
Pilot Air Inlet Hole
104415-01M