10.Combination Switch (Light)
A: REMOVAL
1) Disconnect the ground cable from battery.
2) Remove the instrument panel lower cover. <Ref.
to EI-43, REMOVAL, Instrument Panel Assembly.>
3) Remove the screws which secure the upper col-
umn cover to lower column cover.
4) Disconnect the connector from combination
switch.
5) Remove the screws which secure the switch,
and then remove the switch.
B: INSTALLATION
Install in the reverse order of removal.
Combination Switch (Light)
C: INSPECTION
Measure the combination switch resistance.
LI-00009
1. LIGHTING SWITCH
LHD model and RHD for Europe model:
LI-00068
RHD except for Europe model:
LI-11
(A)
8
7
6 5 4
17
16
1514131211 10
(B)
8
7
6
17
16
1514131211 10
(A) LHD model/RHD model (for Europe)
(B) RHD model (Except for Europe)
Switch position
Terminal No.
OFF
—
Tail
14 and 16
Head
13, 14 and 16
Switch position
Terminal No.
OFF
—
Tail
9 and 15
Head
9, 14 and 15
LIGHTING SYSTEM
3
2
1
9
5 4 3
2
1
9
LI-00184
Standard
More than 1 MΩ
Less than 1 Ω
Less than 1 Ω
Standard
More than 1 MΩ
Less than 1 Ω
Less than 1 Ω