4.31 Lap belt

The lap belt kit.
(Fig. 10).
Fastening the lap strap.
Insert the 3 prong male buckle into
the female buckle until a click is
heard
(Fig. 11)
To fit the lap strap.
Place the strap loosely across the
seat with the buckle closed..
12)
Pass the other ends of the strap
through the gap between the
backrest posts and the backrest
upholstery as shown. (Fig. 13)
Ensure that the adjusters & buckles
can be accessed & the strap is not
twisted. Fit the eyelet over the
rearmost bolt. Fit the plain washer,
sprung washer & nut. Tighten with
a 13.0mm spanner. Repeat for the
other side. (Fig 14)
Ensure that the lap strap is tight
enough to provide comfortable
support. A simple measure is to
keep a hands thickness between the
body and lap strap. For safety, check
the tension on the lap strap at least
once day. (Fig 15)
Generally, the lap belt should be
fixed so that the straps sit at an angle
of approximately 45°
(Fig.
16), and when
correctly adjusted should not allow the user
to slip down in the seat.
Warning - Always make sure that the lap
strap is correctly secured and adjusted prior
to use.
A loose strap could cause the user to slip
down and cause serious injury.
Check lap strap and securing components at regular intervals for any
signs of fray or damage. Replace if necessary
When servicing, check for correct operation of the release buckle and
for any signs of wear on the material or plastic brackets
060474
Fig. 10
Fig. 11
Fig. 12
(Fig.
Fig. 13
Fig. 14
Fig. 15
Fig. 16
4.32 VR2 Controller (Fig. 17)
Avoid knocking your control system and especially the joystick. Be
careful not to strike obstacles with the control system or joystick when
you drive. Never drop the control system.
When transporting your wheelchair, make sure that the control system
is well protected. Avoid damage to cables.
To improve the reliability of the control system keep exposure to
extreme conditions to a minimum.
Do not expose your control system or its components to damp for
prolonged periods. If your control system becomes contaminated with
food or drink clean it off as soon as possible.
Controller precautions for use
In the event of the wheelchair moving in an unexpected way RELEASE
THE JOYSTICK. This action will stop the wheelchair under any
circumstances
Do not operate the control system if the wheelchair behaves erratically
or shows abnormal signs of heating, sparks or smoke. Turn the control
system off at once and consult your Sunrise Medical Authorised
Dealer.
Battery Level Indicator
Horn
Speed Buttons
Joystick
On/Off Button
Speed Indicator
Fig. 17